If a second PC is not available simply power up the second modem. Configure the modem connected to the
PC in the repeater mode with the address mode switched off. This will command the distant modem to repeat
back the characters sent to it.

6.0 CONFIGURATION


6.1

Communication Port Menu

The Communication Port Menu is displayed by connecting a PC configured at the Baud Rate set previously
(Factory set at 9600).

Use the three position Program Switch to select either Modem 1 or Modem 2

Press the Alarm Accept button then type $ and then press the Esc key. The following menu should then
appear.

Repeat the above procedure with the Program Switch set to the alternative position.

After exiting the menu return the Program Switch to the vertical position and press the Alarm Accept button.
























The menu parameters are change by pressing any of the four Arrow Keys

Main Menu

Advanced Menu: Pressing the right Arrow Key will display Advanced Menu

.


Modem ID

A user defined ID number can be set. This is used in to set up a Repeater Chain, in the
Remote Access Mode and with the ATA instruction.


Baud

Baud Rate 1.2K to 38.4K can be set. Factor set at 9600 Baud

Warwick Wireless Ltd
X7200-2 Radio Modem V1.0

Local

Remote

Advanced Menu N

N

Modem ID

00

01

Baud Rate 9600

9600

Parity

N

N

Odd/Even

E

E

RF Power

5

5

RF Channel 17

17

Key Transmitter N

N

RSSI N

N

Txmitter Speed

S

S

Address Mode

N

N

TX Address

00

00

RX Address

00

00

RF Sensitivity 50 50
Restore Defaults

N

N

Exit without Save N

N

Save & Exit

N

N

Warwick Wireless Ltd

Advanced Menu

Local

Remote

Return to Main Menu

N

N

Enable AT Instructions

N

N

TX Priority

N

N

Display Journal

N

N

Packetise Data

N

N

Number of Retries

05

05

Packet Size

256

256

Logger Mode

N

N

Enable Remote Access

N

N

Access Remote

N

N

Enable Repeater Path

N

N

Set Repeater Path

00

00


Local

M01 M02 M03 M04 M05 M06 M07 M08

M09 M10 M11 M12 M13 M14 M15 M16


Remote M01 M02 M03 M04 M05 M06 M07 M08

M09 M10 M11 M12 M13 M14 M15 M16