Page 27
E-3
Maintenance
Crossover® Ignition System Operations
If the Crossover Ignition System fails to ignite the Left
burner, light the Left burner with a match. If the Left burner
lights with a match, then check the Crossover Ignition
System.
■ Check that both the white(1) and black(2) ignition wires
are attached properly.
■ Check that the Crossover Ignition button pushes the
igniter (button) down, and returns to the up position.
■ Check to see if the igniter is loose in the frame. Tighten if
necessary; See Step “Install igniter” for correct procedure.
If the Crossover Ignition System still fails to light, Contact
the Customer Service Representative in your region using
the contact information sheet provided with your manual.
(1)
(2)
9) Reinstall the Spider Stopper Guards. Slightly rotate
the Spider Stopper Guards so that the seams are in
line with the Venturi fins(1). There should be no
gaps in the seams or in the fit around the burn-
ers(2) and valves(3).
ƽ CAUTION: If the Spider Stopper Guards do not fit
tightly, contact the Customer Service Representa-
tive in your region using the contact information
sheet provided with your manual.
ƽ WARNING: After reinstalling the gas lines, they
should be leak checked with a soap and water
solution before using the barbecue. (See Step:
“Check for gas leaks.”)
(3)
(2)
(1)