beautypg.com

Wasp Bar Code CCD - 80SIR User Manual

Page 18

background image

4.2 Code Mark ( Code ID) Parameters

You may use the example listed below to define the
code mark for your own applications.

Please note that each code mark you define
has to follow the steps as example shown
below . You may also refer to Chapter 5
for details.

For example: to define " Z " as code mark for code 39. , the
steps will be as under :

a) Scan " Start " label.
b) Scan Code 39 label as below.
c) Refer to Appendix A. ASCII Code Table where shows
" 5" "A" stand for " Z".
d) From Appendix D. Hex-Label to scan " 5" "A" labels.
e) Scan " EXIT" label also from Hex-Label Table.
f) Scan " END" to complete your definition

Code Mark Parameters

Code 39

IND 2/5

CODABAR

EAN-8

Code 128

ITF 2/5

MTX 2/5

EAN-13/UPC-A

UPC-E

Note: 1. Read code type and then CANCEL label.

2. Please follow the rule for cancellation step by
step, i.e.: to read one code type and then
scan CANCEL label.

CANCEL

27

4.3 Pre-amble and Post-amble

Pre-amble & Post-amble

Pre-amble=??

Post-amble=??

Note: 1. You can define maximum 10
characters/digits for each pre-/post-amble.

2. Please refer to examples in Chapter 5.

Cancellation of Pre-amble & Post-amble

Pre-amble

Post-amble

CANCEL

Note: Read pre-amble for post-amble first and then
CANCEL label afterwards.

4.4 Buzzer Parameters

Buzzer Pitch & Duration

Buzzer pitch=?? (0-22)

Buzzer duration=?? (0-127)

Buzzer parameters include buzzer pitch ( buzzer
frequency) and buzzer duration.

28