Wolf cooktop ventilation recommendations – Wolf CTWH36 User Manual
Page 9

Planning Information
Wolf Cooktop Ventilation Recommendations
9
Dimensions in parentheses are in
millimeters unless otherwise specified.
C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O N S
Cooktop Hoods, Downdrafts and Pro Hoods
CTWH30
CTWH36
IH4227
DD30
DD36
DD45
Pro Hoods
Electric Cooktops
Model CT15E
215*
215*
215*
215*
150*
215*
Model CT30E
450
600
600
500
350
600
Model CT30EU
450
600
600
600
Model CT36E
600
600
500
600
Model CT36EU
600
600
600
CTWH30
CTWH36
IH4227
DD30
DD36
DD45
Pro Hoods
Gas Cooktops
Model CT15G
215*
215*
215*
215*
150*
215*
Model CT30G
450
600
600
500
350
600
Model CT36G
600
600
500
600
CTWH30
CTWH36
IH4227
DD30
DD36
DD45
Pro Hoods
Modules
Model CT15I
215*
215*
215*
215*
150*
215*
Model IG15
215*
215*
215*
215*
Model IS15
215*
215*
215*
215*
Model IF15
215*
215*
215*
215*
Model IM15
215*
215*
215*
215*
150*
215*
*Use these requirements to determine total CFM when installing multiple cooktops or modules.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW).
Additional CFM may be required for long duct runs.
C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S
Cooktop Ventilation Hoods
Blower Description
Blower Number
Cooktop Hood Models
450 CFM Internal
CTBLOWER-45INT (801643)
CTWH30
600 CFM Internal
CTBLOWER-60INT (801644)
CTWH36 / IH4227
900 CFM Internal
CTBLOWER-90INT (801645)
CTWH36 / IH4227
600 CFM In-Line
BLOWER-60IL (808331)
CTWH30 / CTWH36 / IH4227
1100 CFM In-Line
BLOWER-110IL (808332)
CTWH30 / CTWH36 / IH4227
600 CFM Remote
BLOWER-60REM (801640)
CTWH30 / CTWH36 / IH4227
900 CFM Remote
BLOWER-90REM (801641)
CTWH30 / CTWH36 / IH4227
1200 CFM Remote
BLOWER-120REM (801642)
CTWH30 / CTWH36 / IH4227
1500 CFM Remote
BLOWER-150REM (804701)
CTWH30 / CTWH36 / IH4227
Vertical discharge with 8" (203) round duct for wall and island hoods. Transition is not required for internal blowers; in-line and remote
blowers require TRANS-8-10. Backdraft damper included with wall and island hoods.
Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product.
Always consult a qualified HVAC Engineer for specific applications.