Planning Information

Model CTWH36 Cooktop Wall Hood

6

Dimensions in parentheses are in
millimeters unless otherwise specified.

(B)

FLOOR TO

COUNTERTOP

HEIGHT

(A)

TOTAL

FLOOR TO

CEILING

HEIGHT

(C)

COUNTERTOP

TO BOTTOM

OF HOOD

(F)

MAXIMUM

HEIGHT OF

HOOD

(D)

BOTTOM

OF HOOD TO

MINIMUM FLUE

EXTENSION

(E)

UPPER FLUE TOTAL

HEIGHT TO CEILING

C O O K T O P H O O D P L A C E M E N T

Wolf cooktop wall ventilation hoods come with a telescopic

chimney flue that allows you to reach a ceiling height of 8' (2.4 m)

to 9' (2.7 m) with a finished look. A flue extension to accommo-

date 10' (3 m) ceilings is available as a sales accessory.

Installation of the wall hood should be 24" (610) to 30" (762)

from the bottom of the hood to the countertop.

IMPORTANT NOTE: 8' (2.4 m) ceilings will not allow for a 30"
(762) maximum height above the countertop. Based on a 36"
(914) high countertop, an 8' (2.4 m) ceiling will allow for a
maximum height above the countertop of 27

5

/

16

" (694).

IMPORTANT NOTE: Both sections of the telescopic chimney flue
must be installed in order for the chimney to be lifted for service.

To determine placement of the cooktop wall hood, you must

calculate the height of the telescopic chimney flue. Refer to the

illustration and chart below.

To calculate the height of the telescopic chimney flue:

1) First measure A (total kitchen height from finished floor to

finished ceiling height).

2) Next measure B (height from finished floor to countertop).

3) Then determine the minimum C value (distance from

countertop to bottom of hood). Refer to the chart for ceiling

heights from 8' (2.4 m) to 9' (2.7 m). Dimension C must be

greater than 24" (610) and less than 30" (762).

4) To determine the upper flue section height: E=A-(C+B+D).

IMPORTANT NOTE: If dimension E falls between 0" (0) and

1

/

2

" (13), you will need to modify the flue to affix to the flue

attachment brackets. For ease of installation, Wolf

recommends that dimension E be no less than

1

/

2

" (13).

M O D E L C T W H 3 6

(A)

(B)

(C)

(D)

(E)

(F)

96" (2438)

36" (914)

24" (610) min

32

11

/

16

" (830)

3

5

/

16

" (84)

50

7

/

8

" (1292)

96" (2438)

36" (914)

27

5

/

16

" (694) max

32

11

/

16

" (830)

0"

50

7

/

8

" (1292)

108" (2743)

36" (914)

24" (610) min

32

11

/

16

" (830)

15

7

/

16

" (392)

50

7

/

8

" (1292)

108" (2743)

36" (914)

30" (762) max

32

11

/

16

" (830)

9

5

/

16

" (237)

50

7

/

8

" (1292)

Letters correspond to those in the illustration.