beautypg.com

Caution – White Rodgers 1F92-71 User Manual

Page 15

background image

15

A cooling anticipation setting of less
than 10 may cause decreased com-
pressor life.

To adjust HEAT anticipation, press

SET

CLOCK

and

SET
DAY

at the same time. The display will

show HEAT 18. You may select any antici-
pation setting from 4 to 40 (note that for
add-on heat pump systems, a minimum
anticipation of 10 is recommended)
.
Whenever adjusting anticipation, increase
or decrease the displayed number by only
one or two digits, then let the system run
for a while to see if the adjustment is
sufficient. If the heat cycles are too short,

press

TIME
FWD

to increase the cycle time. If the

heat cycles are too long, press

TIME

BACK

to

decrease the cycle time. To set COOL

anticipation, press

SET

CLOCK

and

SET
DAY

at the

same time again. The display will show
COOL 14 (factory preprogrammed cool-

ing anticipation). Use

TIME
FWD

and

TIME

BACK

to

adjust anticipation. To set AUXILIARY
heat anticipation (not applicable to multi-

stage use), press

SET

CLOCK

and

SET
DAY

at the

same time again. The display will show
AUX 8 (factory preprogrammed auxiliary

anticipation). Use

TIME
FWD

and

TIME

BACK

to adjust

anticipation. Press

RUN

PRGM

to return to your

program.

CAUTION

!