Heating system, Cooling system, Caution – White Rodgers 875 User Manual

Page 3

background image

3

RH

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 2. Typical wiring diagram for

heat only, 3-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Y

C‡

RC

JUMPER

WIRE

O

B

For 2-wire Heat only,
attach to RH and W

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

TRANSFORMER

THERMOSTAT

SYSTEM

G

W

Figure 3. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Cooling
System

Fan

Relay

RC

O

B

C‡

JUMPER

WIRE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 4. Typical wiring diagram for

heat/cool, 4-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

JUMPER

WIRE

O

C‡

B

RED jumper wire (provided with thermostat) must be
connected between thermostat RH and RC terminals
for proper thermostat operation with this system.

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 5. Typical wiring diagram for

heat/cool, 5-wire, two-transformer systems

HEATING

TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

24 VAC

120 VAC

Hot

Neutral

COOLING TRANSFORMER

O

B

C‡

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 6. Typical wiring diagram for heat pump

with reversing valve energized in COOL

TRANSFORMER

Reversing

Valve*

RC

O

B

C‡

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the COOL position

Fan

Relay

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 7. Typical wiring diagram for heat pump

with reversing valve energized in HEAT

TRANSFORMER

Reversing

Valve*

RC

O

B

C‡

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the HEAT position

Fan

Relay

The 24 Volt neutral connection to terminal C on the thermostat is not required if the batteries are replaced once a

year with fresh “AA” alkaline batteries.

Heating System

1. Move SYSTEM switch to HEAT position. If the heating system

has a standing pilot, be sure to light it.

2. Press

to adjust thermostat setting above room tempera-

ture. The heating system should begin to operate.

3. Press

to adjust thermostat setting below room tempera-

ture. The heating system should stop operating.

1. Move SYSTEM switch to COOL position.

2. Press

to adjust thermostat setting below room tempera-

ture. The blower should come on immediately on high speed,
followed by cold air circulation

3. Press

to adjust thermostat setting above room tempera-

ture. The cooling system should stop operating.

Cooling System

To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.

CAUTION

!