beautypg.com

Installation, Remove old thermostat, Attach thermostat base to wall – White Rodgers 875 User Manual

Page 2: Check thermostat operation

background image

2

Mounting

holes

Mounting

holes

Electric/Gas

switch

Screw anchors

INSTALLATION

REMOVE OLD THERMOSTAT

1. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

2. Remove the front cover of the old thermostat. With wires

still attached, remove wall plate from the wall. If the old
thermostat has a wall mounting plate, remove the thermostat
and the wall mounting plate as an assembly.

3. Identify each wire attached to the old thermostat using

the labels enclosed with the new thermostat.

4. Disconnect the wires from old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

5. Install new thermostat using the following procedures.

ATTENTION!

This product does not contain mercury. However, this product
may replace a unit which contains mercury.

Do not open mercury cells. If a cell becomes damaged, do not
touch any spilled mercury. Wearing nonabsorbent gloves, take
up the spilled mercury with sand or other absorbent material and
place into a container which can be sealed. If a cell becomes
damaged, the unit should be discarded.

Mercury must not be discarded in household trash. When the
unit this product is replacing is to be discarded, place in a suit-
able container and return to 2895 Harrison Street, Batesville,
AR 72501 for proper disposal.

ELECTRIC HEAT OR SINGLE-STAGE

HEAT PUMP SYSTEMS

This thermostat is confi gured from the factory to operate a heat/
cool, fossil fuel (gas, oil, etc.), forced air system. It is confi gured
correctly for any system that DOES NOT require the thermostat
to energize the fan on a call for heat. If your system is an electric
heat or heat-pump system that REQUIRES the thermostat to
turn on the fan on a call for heat, locate the ELECTRIC/GAS
switch
on the back of the thermostat (see fi g. 1) and switch
it to the ELECTRIC position. This will allow the thermostat
to energize the fan immediately on a call for heat. If you are
unsure if the heating/cooling system requires the thermostat to
control the fan, contact a qualifi ed heating and air conditioning
service person.

ATTACH THERMOSTAT BASE TO WALL

1. Remove the packing material from the thermostat. Gently

pull the cover straight off the base. Forcing or prying on the
thermostat will cause damage to the unit. If necessary, move
the electric heat switch (see ELECTRIC HEAT SYSTEMS,
above).

2. Connect wires beneath terminal screws on base using ap-

propriate wiring schematic (see fi gs. 2 through 7).

3. Place base over hole in wall and mark mounting hole loca-

tions on wall using base as a template.

4. Move base out of the way. Drill mounting holes.

5. Fasten base loosely to wall, as shown in fi g. 1, using two

mounting screws. Place a level against bottom of base,
adjust until level, and then tighten screws. (Leveling is for
appearance only and will not affect thermostat operation.)
If you are using existing mounting holes, or if holes drilled
are too large and do not allow you to tighten base snugly,
use plastic screw anchors to secure subbase.

6. Push excess wire into wall and plug hole with a fi re-resistant

material (such as fi berglass insulation) to prevent drafts from
affecting thermostat operation.

BATTERY LOCATION

2 “AA” alkaline batteries are included in the thermostat at the
factory with a battery tag to prevent power drainage. You must
remove the battery tag to engage the batteries.

If “BATT” is displayed, the batteries are low and should be re-
placed. For best results, replace all batteries with new premium
brand batteries such as Duracell

®

or Energizer

®

. To replace

batteries, install the batteries along the top of the base (see
Fig. 1). The batteries must be installed with the positive (+) end
to the left.

HYDRONIC (HOT WATER OR STEAM)

HEATING SYSTEMS

This thermostat is set to operate properly with a forced-air heat-
ing system. If you have a hydronic heating system (a system
that heats with hot water or steam), you must set the thermostat
to operate properly with your system. Change the second op-
tion in the confi guration menu to SL (see CONFIGURATION
MENU, page 4).

CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate
properly, contact a qualifi ed service person.

Turn on power to the system.

Fan Operation

If your system does not have a G terminal connection, skip to
Heating System.

1. Move FAN switch to ON position. The blower should begin

to operate.

2. Move FAN switch to AUTO position. The blower should
stop

immediately.

Figure 1. Thermostat Base