Temperature

Temperature (Factory set to 204 °F)

Press  to Select. Press < or > to move to desired temperature and then  to set. Temperature is programmable

from 170ºF to 204ºF in 2-degree increments.

Energy Save Mode (Factory set to OFF)

Press  to Select, < or > ON, OFF or ON 140ºF ,  to set. When in ON, unit will automatically shut off 4 hours

from last brew. When feature is OFF, unit does not have the energy saving mode.

In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save

energy by maintainig a lower temperature in the tank during periods of non-operation.

Energy Save Mode

Brew Count Total

Press  to Select, Shows total gallons and total brew cycles on the unit. Not resettable.

Cold Brew Lock . . . (Factory set to 5º F)

Press  to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set

point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30

degrees of set point for the Ready to Brew message, however it will brew at any temperature.

Master Reset

Press  to display Are You Sure?

Then < for Yes, > for No.

Brewer factory defaults are then reset.

Service Call (Phone number Factory set to [800] 995-0417)

Press  to display number and change number or < to move place and EX to exit when complete. This number

will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1-2-3-4)

Press  to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to

exit when complete.

Banner Name (Factory set to WILBUR CURTIS)

Press  to display letters and change letters or < to move place and EX to exit when complete

This feature allows up to 14 letters to be programmed for company name or regional name. Programming all

blanks disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.

P-Maintenance (Factory set to OFF)

Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.

Press  to exit.

Beeper On/Off (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature

allows you to hear a short beep each time a button is pressed.

Model Select

Press  to Select. Display TCT G3 .

Master Reset

Service Call

Access Code

Banner Name

P-Maintenance

Brew Count Total

Cold Brew Lock

Beeper On/Off

Exit

Exit

Press  to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.

Brew Count Odom.

Press  to display total brew cycles. Press ex or Reset

Brew Count Odom

PROGRAM MENUS CONTINUED

Model Select

Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will

be displayed (temperature in heating tank).

3