4. Remove the cap from the gas pressure regulator using a

flat-blade screwdriver.

NOTE: Do not remove the spring beneath the cap.

5. Turn the cap over so the LP is visible.

6. Reinstall the cap.

To Convert Surface Burners

1. Remove burner grate, burner caps and burners.

2. Locate LP gas orifice spuds for top burners in the literature

bag included with the range. Two LP gas spuds are stamped
“88” and two “78.”

3. Remove Natural gas orifice spuds using a 7 mm combination

wrench.

4. Install LP gas orifice spuds using a 7 mm combination

wrench.

NOTE: This range cooktop is equipped with 2 standard
burners and 2 super burners. Spud size and location remain
the same.

5. Place the Natural gas orifice spuds in the parts bag for future

use and keep with the bag containing literature.

6. Reinstall burners, burner caps and burner grates.

A. Cap

A. Cap

A. Burner cap
B. Burner

A

A

A

B

A. Spud
B. Holder

A

B

2 super

burners. Spud size/location rem ain the sam e.

Standard

Burner 78

Super

Burner 88

Standard

Burner 78

Super

Burner 88