1. The ER feature can be used to save energy and aids in extending the life of the system.
2. The ER button is located at the top L/H side of the control. The ER feature is activated by
pressing the ER button one time, and the ER logo will appear on the digital display.
3. The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up by 4
degrees, which will allow the cooling system to run for shorter periods of time, resulting
in a reduction in energy cost.
4. The ER feature allows for Energy Savings at any time - During periods of high ambient
temperatures, vacations or business travel.
5. To deactivate the ER feature, press the ER button one time, and the ER logo will turn off.
6. The ER feature can be conveniently adjusted to the customer’s specific needs, by accessing
the “Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode
Instructions.
1. Press the “Set” button once and it will display the Set Point. After approximately 5 sec-
onds, the display will return to normal operation and display the Bottle Probe tempera-
ture.
2. Press and hold the “Set” button for 3-5 seconds until the set point is displayed and the °F
symbol starts blinking. Next press the “UP or Down” arrows to change the Set Point. Next
press the “Set” button once and the Set Point numbers and the °F on the display will blink
to confirm the new Set Point setting.
3. Press the “Set” and the “Down Arrow” buttons simultaneously, for 3-5 seconds, and you will
access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the customer
to “Fine Tune” the Control Operating System to their applicable choice.
The “Customer Preference Selection Mode” (CPSM) allows the customer to fine tune the con-
trol operating system to their specific needs.
• Press the “Set” and the Down Arrow” buttons simultaneously for 3-5 seconds and the dis-
play will show CF, and the F symbol in the top right corner will be blinking.
• Press the “Set” and “Down Arrow Buttons” again but this time hold for 5-7 seconds, this will
activate the “Customer Preference Selection Mode” (CPSM).
The following CPSM options are available for adjustment:
• Fon – Humidity Management Enhancement: This parameter is normally set at 5, which
should provide adequate relative humidity for the cellar.
• An increase in this parameter will increase the Humidity Enhancement (%RH), and a
decrease in the parameter will decrease Humidity Enhancement (%RH).
• Adjustments should be made in increments of 5, with a maximum of 15, and a mini-
mum of 0.
• After any adjustment to Humidity Enhancement, you should wait a minimum of three
days before making any additional adjustments. This will allow the cellar sufficient time