beautypg.com

System operation: standard & remote – WhisperKool Slimline 2500 User Manual

Page 14

background image

Page 14

SL 072710

Initial Start-Up

When power is applied to the unit, the control will

briefly display all symbols, and the Compressor

symbol will be displayed (if unit is calling for cooling).

There may be a brief delay prior to the evaporator

and condenser fans turning on.

Normal System Cycle

After the bottle probe has reached the set point (all

units are shipped with the set point of 55°F and a

differential of 1°F). The WHM is an adjustable fea-

ture which allows the customer the convenience of

managing the humidity enhancement of their wine

cellar. The WHM is one of the many Customer Prefer-

ence Selection features which allow the customer the

ability to fine tune the controls. This feature is set to 0

when shipped but if needed can be adjusted.

Anti Short Cycle

The Anti Short Cycle ensures that the unit will remain

off for a period of 5 minutes after the unit has reached

the set point to allow the pressure in the refrigeration

system to equalize prior to starting the compressor.

Defrost Cycle

The Defrost Cycle is a precautionary measure, as icing

or frosting of the coil does not occur during normal

operation. The system will go through a defrost cycle

every 4 hours. During the defrost cycle, the in-cellar

fan will provide air flow across the in-cellar coil, which

will evaporate any frost accumulation.

Bottle Probe Failure Protection

In the event that a bottle probe should fail, the APST

(Advance Product Safety Technology) will automati-

cally transition the Refrigeration Compressor cycles

to a pre-determined time series (based on detailed

laboratory testing), which will ensure that the prod-

uct is kept within the safe range.

SYSTEM OPERATION: STANDARD & REMOTE