Electrical Requirements

Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical
connection:

Recommended Grounding Method

Plug 1: A 115 Volt, 60 Hz., AC only 15 or 20 ampere fused,
grounded (earthed) electrical supply is required.

Plugs 2 and 3: A 220/240 Volt/50 Hz or 220 Volt/60Hz AC
only 10 ampere fused and grounded (earthed) electrical
supply is required.

It is recommended that a separate circuit serving only your
refrigerator be provided. Use an outlet that cannot be
turned off by a switch. Do not use an extension cord.

NOTE: Before performing any type of installation, cleaning,
or removing a light bulb, turn the control, (Thermostat,
Refrigerator or Freezer Control depending on the model) to
OFF and then disconnect the refrigerator from the
electrical source. When you are finished, reconnect the
refrigerator to the electrical source and reset the control
(Thermostat, Refrigerator or Freezer Control depending on
the model) to the desired setting.

Connecting the Refrigerator

to a Water Source

Read all directions carefully before you begin.

IMPORTANT:

If operating the refrigerator before installing the water
connection, turn ice maker to the OFF position to
prevent operation without water.

All installations must be in accordance with local
plumbing code requirements.

Use copper tubing and check for leaks.

Install copper tubing only in areas where temperatures
will remain above freezing.

It may take up to 24 hours for your ice maker to begin
producing ice.

Tools required:

Standard screwdriver

⁷⁄₁₆-inch and ¹⁄₂-inch open-end wrenches or two
adjustable wrenches

¹⁄₄-inch nut driver

¹⁄₄-inch drill bit

Hand drill or electric drill (properly grounded)

NOTE: Your refrigerator dealer has a kit available with a
¹⁄₄-inch saddle-type shut-off valve, a union, and copper
tubing. Before purchasing, make sure a saddle-type valve
complies with your local plumbing codes. Do not use a
piercing-type or

³⁄₁₆-inch saddle valve which reduces water

flow and clogs more easily.

Cold Water Supply

The ice maker water valve contains a flow washer which is
used as a water pressure regulator. The ice maker needs to
be connected to a cold water line with water pressure
between 30 and 120 psi. If a problem occurs, call your
utility company.

Connecting to water line:

1. Unplug refrigerator or disconnect power.

2. Turn OFF main water supply. Turn ON nearest faucet

long enough to clear line of water.

3. Find a

¹⁄₂-inch to 1¹⁄₄-inch vertical COLD water pipe

near the refrigerator.

NOTE: Horizontal pipe will work, but the following
procedure must be followed: Drill on the top side of the
pipe, not the bottom. This will help keep water away
from the drill. This also keeps normal sediment from
collecting in the valve.

WARNING

Electrical Shock Hazard

Plug into a grounded (earthed) outlet.

Failure to follow these instructions can result in
death, fire, or electrical shock.

Do not use an extension cord.

Do not use an adapter.

Do not remove ground prong.

Plug 1

Plug 2

Plug 3