beautypg.com

Annual maintenance requirements – Williams 2903512 User Manual

Page 16

background image

Annual Maintenance Requirements



1. Clean fan blades.



2. Clean air blower.








3. Check and clean silicone red pipes.

4. Check air flow switch.

5. Clean and check exhaust flue pipe and air intake pipe.

Check red O-Ring Gasket
(NRNG003). If it is
damaged, replace it.






6. Check for gas leaks on all connections.

7. Check and adjust gas pressure.

























Gas inlet pressure
(pipeline)

Gas burner
adjustment

Gas

manifold
pressure
(burner)

pressure

15

This manual is related to the following products: