Multi-function cooktop specifications, Electrical requirements – Wolf Appliance Company IM15 User Manual
Page 8
Multi-Function Cooktop Specifications
8
Electrical Requirements
The Wolf multi-function cooktop requires a 120 V AC,
60 Hz, 15-amp, fused electrical supply. A time-delay fuse
or circuit breaker is recommended. It is recommended that
a separate circuit serving only this appliance be provided.
A ground fault circuit interrupter (GFCI) is not recom-
mended and may cause interruption of operation.
ELECTRICAL GROUND
The 6'
(1.8 m)
power cord is equipped with a 3-prong,
grounding plug for protection against shock hazard. The
power cord must be plugged into a mating 3-prong
grounded outlet, grounded to conform with the National
Electrical Code, ANSI/NFPA 70 latest edition, or Canadian
Electrical Code (CSA) and all local codes and ordinances.
Refer to the illustration below.
IMPORTANT NOTE:
This appliance must be properly
grounded to avoid electrical shock hazard. Do not ground
to a gas pipe.
GROUNDING
PLUG
GROUNDED
ELECTRICAL OUTLET
Electrical ground.
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove ground prong. Do not
use an adapter. Failure to follow these instructions can
result in electric shock, fire or death.
N
A
1
1
2
2
BLACK
BLACK
WHITE
WHITE
RED
WHITE
RED
WHITE
RED
SPARK
MODULE
3 CONDUCTOR
POWER CORD
GRN
BLK
IMPORTANT NOTE:
Electronic ignition systems operate
within wide voltage limits, but proper ground and polarity
are necessary. In addition to checking that the electrical
outlet provides 120 V AC power and is correctly grounded,
the outlet must be checked by a qualified electrician to
see if it is wired with correct polarity.
WIRING DIAGRAM
The wiring diagram below covers the control circuit for the
Wolf multi-function cooktop.
Wiring diagram.