beautypg.com

Replacement parts, Removing the manifold assembly, Removing the burner from the manifold assembly – Whirlpool Energy Smart W10100870 User Manual

Page 21: Natural gas burner (low nox)

background image

21

Replacement Parts

IMPORTANT: The following maintenance procedures
are for the Flame Lock

Safety System components and

should be performed by a qualified person.

Replacement parts may be ordered through your plumber
or the local distributor. Parts will be shipped at prevailing
prices and billed accordingly. When ordering replacement
parts, always have the following information ready:

1. model, serial, and product number

2. type

of

gas

3. item

number

4. parts

description

See pages 27-28 for a list of available repair parts.

Removing the Manifold Assembly

1. Turn off the gas to the water heater at the manual gas

shut-off valve (Figure 3).

2. Turn the gas control/temperature knob to the “OFF”

position (Figure 19).

3. Remove the outer door.

4. Remove the two screws

securing the manifold door
to the combustion chamber
(Figure 23).

5. Disconnect

the

thermopile,

pilot tube, the igniter wire
from the igniter button, the
two connectors attached
to the thermal switch, and
manifold tube at the gas
control valve/thermostat.
(Figures 22 & 23.)

6. Grasp the manifold tube

and push down slightly to
free the manifold tube, pilot tube, and thermopile.

7. Carefully remove the manifold assembly from the

combustion chamber. NOTE: Be sure not to damage
internal parts.

Removing the Burner from the
Manifold Assembly

Natural Gas Burner (Low Nox)

1. Take off the burner by removing the two (2) screws

located underneath the burner.

2. Check the burner to see if it is dirty or clogged. The

burner may be cleaned with soap and hot water (Figure
24).

Figure 22
Gas Control Valve/
Thermostat

Igniter
Wire

Thermopile Wire

Pilot Tube

Manifold
Tube

Igniter
Button

Figure 23
Manifold Assembly
Removal

Manifold Screw (2)

Two Piece Wire Connector

Manifold Door

Thermal Switch

Pilot Tube

Manifold Tube

Viewport

Thermopile

Piezo Igniter Button

Gas Valve/Thermostat

Figure 24
Natural gas (Low NOx)
Manifold Assembly

Pilot Assembly

Burner

Thermal Switch

Viewport

Manifold Door

Door Gasket

Thermopile

Pilot Tube

Manifold Tube

Two Piece Wire

Connector

Pilot Bracket

Igniter Wire

Screws

Burners

Pilot Assembly

Manifold Tube

Manifold Door

Pilot Tube

Thermopile Connector

This manual is related to the following products: