To prevent electrical shock and/or equipment
damage, disconnect electrical power to system,
at main fuse or circuit breaker, until installation is
complete.

To prevent personal injury and/or equipment dam-
age, check equipment manufacturer’s wiring of
fan relay circuit when in EMER HEAT. When the
thermostat system switch is in the EMER HEAT
position, the thermostat DOES NOT energize the
fan relay when the fan switch is in the AUTO
position.

This typical wiring diagram shows only the terminal iden-
tification and wiring hookup. Always refer to wiring
instructions provided by equipment manufacturer for sys-
tem hookup.

All wiring should be installed in accordance with local and
national codes and ordinances.

CAUTION

!

NOTE

FAN CAUTION

!

THERMOSTAT

SUBBASE

HEAT PUMP

SYSTEM

Figure 2. Typical wiring diagram

Fixed Stage 1 Heat
& Cool Anticipator

Adjustable Stage 2

Heat Anticipator

COOL

STAGE 1

HEAT

STAGE 2

HEAT

System

Switch

Fan

Switch

TRANSFORMER

24 VAC

120 VAC

ON

COOL

OFF

HEAT

EMER.

COOL

OFF

HEAT

EMER.

FAN

RELAY

SEE FAN

CAUTION

(ABOVE)

EMER. HEAT

RELAY

AUXILIARY

HEAT RELAY

COMPRESSOR

CONTACTOR

Y

W2

E

X1

R

G

B

*

O

*

*

Reversing Valve – if the reversing valve in your heat pump energizes

during HEAT, then make your electrical connection at terminal B on
the subbase. If the reversing valve is energized during COOL, then
make your connection at terminal O on the subbase.

Always refer to equipment manufacturer’s instructions for proper
identification of the reversing valve electrical connections.