beautypg.com

Maintenance & troubleshooting – Windsor DOMINATOR D250 User Manual

Page 8

background image

MAINTENANCE & TROUBLESHOOTING

D-250 98637 1/15/99

8

D-250 PUMP MAINTENANCE

Per manufacturer’s recommendations the following maintenance should be performed
utilizing noted kits:
1.) 500 hours-Kit 55250751 replaces the V-packing, wave washer, packing spreader and

plunger guide.

2.) 500 hours-Kit 55250753 replaces the CAM bearing and insert.
3.) 1000 hours-kit 55250752 valve assembly and o-rings.

NOTE: Maintenance and repairs must be done by qualified personnel. Using non-
Windsor parts to repair this machine will void the warranty. Contact an authorized
Windsor dealer for complete details.

TROUBLE SHOOTING CHART :

PROBLEM

POSSIBLE CAUSE

SOLUTION

No power to

Dead electrical circuit

Check building circuit breaker or fuse

machine

box.

Faulty power cord

Replace.

Electrical shock

Equipment not grounding

Follow grounding instructions exactly.

Receptacle not grounded

Contact an electrician to check
building's wiring.

Internal wiring problem

Have a trained service technician check
machine's wiring.

Vac motor speed

Worn motor brushes

Replace.

varies or doesn't run

Motor worn out

Replace.

Faulty switch

Replace.

Loss of

Loose vacuum dome

Center and seal dome over tank.

Vacuum

Crack in dome or

Replace or repair using acrylic plastic

poor joint

cement only.

Lint or dirt clogging

With power off clean screen.

vacuum screen

Loose cuffs on vacuum

Tighten cuffs turning counterclockwise.

hose

Vac motor seals leaking

Replace.

Floor tool vac chamber

Wash out with hose. Pick lint out with a

clogged

wire.

Vac motor, hose, or

Replace.

dome gasket