Specifications, Ordering information, Your authorized watlow distributor is – Watlow Electric Single and Dual Loop Controller Series PD User Manual
Page 2
Specifications
Power
• 24Vı(ac/dc), +10/-15 percent, 50/60Hz, ±5 percent
• 12VA maximum power consumption
• Data retention upon power failure via nonvolatile memory
Environment
• 0 to 65°C (32 to 149°F) operating temperature
• -40 to 85°C (-40 to 185°F) storage temperature
• 0 to 90 percent RH, non-condensing
Accuracy
• Calibration accuracy and sensor conformity: ±0.1 percent of
span, ±1°C @ the calibrated ambient temperature and rated
line voltage
• Calibration ambient temperature = 25°C ±3°C (77°F ±5°F)
• Accuracy span: 540°C (1000°F) minimum
• Temperature stability: ± 0.1°C/°C (±0.2°F/°F) rise in ambient
maximum
Agency Approvals
• UL
®
508, C-UL
®
, CSA and CE
• ODVA: EtherNet/IP
™
Controller
• Microprocessor-based user-selectable control modes
• Single or dual channel universal inputs
• Current transformer inputs/digital inputs
• Up to four programmable outputs
• Update rates, inputs = 10Hz, outputs = 10Hz
Operator Interface
• Browser based HMI
Wiring Termination
• Touch safe removable terminals
• 14 to 22 AWG
Universal Inputs (Electrically Isolated)
• Thermocouple, grounded or ungrounded sensors
• RTD 2 or 3-wire, platinum, 100
Ω @ 0°C calibration to
DIN curve (0.00385
Ω/Ω/°C)
• Process 0-20mA @ <100
Ω, or 0-10VÎ(dc) @ 10kΩ input
impedance (50,000 bits @ full scale)
Digital Inputs
• Contact or dc voltage
• 10K
Ω input impedance
Current Transformer Inputs
• 0 to 50mA CT input into 100
Ω impedance
Allowable Input Operating Range
Type J:
-200
to
1200°C
or
-340
to
2192°F
Type K:
-270
to
1370°C
or
-454
to
2500°F
Type T:
-270
to
400°C
or
-454
to
750°F
Type N:
-270
to
1300°C
or
-454
to
2372°F
Type E:
-270
to
975°C
or
-454
to
1790°F
Type C:
0
to
2315°C
or
32
to
4200°F
Type D:
0
to
2315°C
or
32
to
4200°F
Type PTII:
0
to
1395°C
or
32
to
2543°F
Type R:
0
to
1760°C
or
32
to
3200°F
Type S:
0
to
1760°C
or
32
to
3200°F
Type B:
0
to
1815°C
or
32
to
3300°F
RTD (DIN):
-200 to
800°C
or
-328
to
1470°F
Process V:
0 to 10VÎ(dc)
Process I:
0 to 20mA
Control/Alarm Outputs (1 - 4)
• User selectable as: on-off, P, PI, PD, PID, heat, cool, alarm
action or retransmit with process output type hardware
• Open collector/switched dc
• Open collector 42VÎ(dc) maximum@ 0.5A
• Switched dc 22 to 28VÎ(dc) limited @30mA
• Solid-state relay, Form A, 0.5A @ 24V~(ac) minimum,
264V~(ac) maximum, opto-isolated, without contact
suppression
• User-selectable 0-10VÎ(dc), 1K
Ω minimum, scalable,
0-20mA @ 800
Ω maximum, scalable
• Electromechanical relay. Form C, rated 5A @ 120V~(ac) or
5A @ 240V~(ac) or 5A @ 30VÎ(dc)
Ordering Information
To order, complete the model number on the right with the
information below.
P D
- _ _ _ _ - _ _ _ _
Control Type
S = Single channel
D = Dual channel
Auxiliary Inputs
1 = Dual digital inputs
2 = One CT input and one digital input
3 = Dual CT inputs (dual channel only)
Output 1
C = Switched dc, open collector
K = SSR, Form A, 0.5A
F = Universal process
J = Mechanical relay, Form A, 2A
Output 2
A = None
C = Switched dc, open collector
K = SSR, Form A, 0.5A
E = Mechanical relay, Form C, 2A
Output 3
A = None
C = Switched dc, open collector
K = SSR, Form A, 0.5A
F = Universal process (If output 1 is F only)
J = Mechanical relay, Form A, 2A
Output 4
A = None
C = Switched dc, open collector
K = SSR, Form A, 0.5A
E = Mechanical relay, Form C, 2A
On Board Data Logging
0 = None
1 = On board data logging
Custom Options
AA = Watlow logo
BB = No logo
Your Authorized Watlow Distributor Is:
Communications
• EtherNet/IP™ with static and dynamic assemblies
• PCCC protocol messages
• TCP/IP/Ethernet
• Modbus™ TCP
• Ethernet RJ 45 connector, 10 base T
• HTTP interface
• DHCP, auto IP or fixed IP address
Dimensions
• Width x height x depth, 42 mm x 116 mm x 132 mm
(1.64 in. x 4.56 in. x 5.19 in.)
• DIN-rail or chassis mount, DIN-rail spec DIN 5022
35 mm x 7.5 mm (1.38 in. x 0.30 in.)
A