Wells WV-4HS User Manual

Page 5

background image

ITEM

a6.



8.


9.


a10.


a11.


12.


a15.


16.


18.




19.


22.


23.


28.


a31.


38.


40.


41.


42.


43.


44.


56.


70.

DESCRIPTION

FIRE SUPPRESSION
AGENT TANK (1.5 gal.)


ADJUSTABLE (FRONT)
LEG


RIGID (REAR) CASTER


MANUAL PULL STATION


FUSIBLE LINKS


LOWER REAR ACCESS
PANEL


DISCHARGE NOZZLE


GREASE BAFFLE


PRE-FILTER ASSEMBLY




HEPA/CHARCOAL FILTER
PACK


GREASE CUP


GREASE TROUGH


VENTILATOR EXHAUST
DUCT


STATUS INDICATOR


POWER CORD


WARMER RELAY


POWER CONTACTOR


BUILDING FIRE ALARM
RELAY


GROUND LUG


INTERLOCK TERMINAL


VENTILATOR FAN


COOLING FAN

COMMENT

Container for Ansulex™ Low-pH liquid fire suppression liquid.


Allows the unit to be leveled.


Allows the unit to be easily positioned by lifting the front of the
unit slightly.


Provides a means of manual activation of the fire suppression
system. PULL ONLY IN CASE OF FIRE!


Automatically activates fire suppression system in the event of
fire on the cooktop.


Allows access to Ansul® fire suppression agent tank (a6) and
controls also access to main power contactor (41).


Fire suppression media discharges here (2 places).


Extracts and drains most grease and moisture from the air flow.

Comprises the PRE-FILTER FRAME and a replaceable
PRE-FILTER. Stops larger particles of grease from
reaching the FILTER PACK for reduced maintenance
costs.

Stops most grease and smoke particles. Also assists in some
cooking odor removal.


Collects grease/moisture drained from grease trough (23).


Directs grease/moisture removed by grease baffle to grease
cup.


Exit point for ventilator airflow - on top left rear of unit.
DO NOT BLOCK


Displays status of fire suppression system (COCKED - FIRED)
If FIRED, a buzzer will sound continuously.


6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).


Provides power to roll warmer section. Energized at all times
except during fire safety shut-down.


Energizes cooktop only while ventilator section is sensed as
operational.


Reports fire alarm condition to building fire management
system.


Ground wire of power cord connects here.


Provides connection for shut-down control by building fire
management system.


Provides air movement for ventilation.


Provides cooling for cooktop controls.

FEATURES & OPERATING CONTROLS (continued)

VENTILATOR SECTION

3

504

p/n

3039

03

o

p

M

W

V

-4H V

entle

ss Ho

tpla

te Coo

k

top