Caution, Maintenance instructions – Wells WPP-10 User Manual
Page 10

ADJUST STIRRER NEUTRAL POSITION 
 
With the kettle switch OFF, the stirrer should land at a position that 
allows the kettle to rotate without binding on the stirrer wand. If the 
stirrer wand does not land positioned left to right, adjust the 
positioning cam: 
1. Disconnect unit from electric power. Remove the top panel. 
 Raise the kettle lid until it is captured by the magnetic holder. 
2. Spin the gearmotor fan by hand until the stirrer wand is positioned 
 left to right (I.e. parallel to the front of the cabinet). 
3. Loosen the positioning cam nut and locknut. Turn the cam until it 
 depresses the pin of the positioning switch. Tighten the cam nut 
 and lock nut. 
4. Reconnect unit to electric power. Press the kettle switch to “ON”. 
 Wait approximately 5 seconds, then press the kettle switch to 
 “OFF”. The stirrer motor will run until the positioning cam activated 
 the positioning switch. 
5. If the stirrer wand stops in the proper left-to-right position, 
 procedure is complete. Otherwise, repeat steps 1 through 4. 
CHANGE HEAT LAMP 
 
1. Press warmer switch “OFF”. Allow unit to cool before replacing 
 lamp. 
2. Squeeze front and rear portions of guard until the front hook clears 
 the slot. Slide the rear hook from its slot, then remove the guard. 
3.
Unthread old heat lamp from its socket and discard.
4.
Thread new heat lamp into socket.
IMPORTANT: Use only 400W safety-coated lamp
5. Reinstall guard.
CAUTION:
INJURY HAZARD
Disconnect appliance from 
electrical power before 
performing any of these 
procedures. 
Adjust Positioning Cam
CAUTION:
BURN HAZARD 
 
Lamp may be hot. 
Allow lamp to cool before 
replacing
.
Change Heat Lamp
MAINTENANCE INSTRUCTIONS
8
232 30622
3
Ow
ners
M
a
nual
W
PP-
Se
ries 
P
opcorn
Popp
er