Basic sst service guide – White Rodgers SST1000 User Manual

Page 10

background image

10

SER

SER

SER

SER

SERVICE INDICA

VICE INDICA

VICE INDICA

VICE INDICA

VICE INDICATION

TION

TION

TION

TION

SERVICE CHECKS

SERVICE CHECKS

SERVICE CHECKS

SERVICE CHECKS

SERVICE CHECKS

ON/OFF switch “ON”

Unit functioning Normally

Unit functioning Normally

Unit functioning Normally

Unit functioning Normally

Unit functioning Normally

Blower ON
Operating Light ON

ON/OFF switch “ON”

1.

1.

1.

1.

1.

Power is not being supplied to air cleaner.

Power is not being supplied to air cleaner.

Power is not being supplied to air cleaner.

Power is not being supplied to air cleaner.

Power is not being supplied to air cleaner.

Blower ON

A. Check fuse or circuit breaker.

Operating Light OFF

B. Ensure power pack is properly installed and latched.

2.

2.

2.

2.

2.

Collecting cell shorted - Turn power Off - Remove power pack - Remove

Collecting cell shorted - Turn power Off - Remove power pack - Remove

Collecting cell shorted - Turn power Off - Remove power pack - Remove

Collecting cell shorted - Turn power Off - Remove power pack - Remove

Collecting cell shorted - Turn power Off - Remove power pack - Remove
collecting cells - Replace power pack - Restore power (ensure blower is

collecting cells - Replace power pack - Restore power (ensure blower is

collecting cells - Replace power pack - Restore power (ensure blower is

collecting cells - Replace power pack - Restore power (ensure blower is

collecting cells - Replace power pack - Restore power (ensure blower is
operating).

operating).

operating).

operating).

operating).
A. If Operating Light comes ON check cells for bent plates, loose ionizing

wire(s) or cracked insulator(s).

B. If Operating Light remains OFF, malfunction is in the power pack. (See

power supply Checkout Procedure).

ON/OFF Switch “ON”

1.

1.

1.

1.

1. Air flow sensor contaminated/misaligned

Air flow sensor contaminated/misaligned

Air flow sensor contaminated/misaligned

Air flow sensor contaminated/misaligned

Air flow sensor contaminated/misaligned

Blower OFF

A. Remove power pack and clear contamination inside black bushing around

Operating Light ON

the small sensor element.

B. Ensure small sensor element is centered in bushing.

2.

2.

2.

2.

2. Air sensor left in bypassed condition after servicing.**

Air sensor left in bypassed condition after servicing.**

Air sensor left in bypassed condition after servicing.**

Air sensor left in bypassed condition after servicing.**

Air sensor left in bypassed condition after servicing.**

3.

3.

3.

3.

3. Faulty air flow sensor panel.

Faulty air flow sensor panel.

Faulty air flow sensor panel.

Faulty air flow sensor panel.

Faulty air flow sensor panel.

Excessive arcing during

1.

1.

1.

1.

1. Wet collecting cell.

Wet collecting cell.

Wet collecting cell.

Wet collecting cell.

Wet collecting cell.

normal operation -

A. Allow cell(s) to dry after cleaning before applying power.

Operating Light may blink

2.

2.

2.

2.

2. Damaged collecting cell(s).

Damaged collecting cell(s).

Damaged collecting cell(s).

Damaged collecting cell(s).

Damaged collecting cell(s).
A. Remove cell(s) and inspect for bent plates, loose ionizing wire(s), cracked

insulator(s), etc.

3.

3.

3.

3.

3. Collecting cells dirty.

Collecting cells dirty.

Collecting cells dirty.

Collecting cells dirty.

Collecting cells dirty.
A. Clean cells as instructed in this manual.

4.

4.

4.

4.

4. Faulty power supply (see power supply checkout procedure)

Faulty power supply (see power supply checkout procedure)

Faulty power supply (see power supply checkout procedure)

Faulty power supply (see power supply checkout procedure)

Faulty power supply (see power supply checkout procedure)

**NO

**NO

**NO

**NO

**NOTE:

TE:

TE:

TE:

TE: Your air cleaner may be equipped with an air flow sensor (switch) which turns the unit ON and OFF in

response to the system blower. It may have been “wired out” during a service check and inadvertently left in this
condition.

BASIC SST SERVICE GUIDE

BASIC SST SERVICE GUIDE

BASIC SST SERVICE GUIDE

BASIC SST SERVICE GUIDE

BASIC SST SERVICE GUIDE

This guide will cover most homeowner complaints. If, after checking the items listed, the unit still fails to operate