Wolf Appliance Company PI423418(R) User Manual
Page 8
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
Planning Information
Pro Island Ventilation Hood
M O D E L P I 4 2 3 4 1 8 ( R )
P R O V E N T I L A T I O N C F M R E C O M M E N D A T I O N S
P R O V E N T I L A T I O N B L O W E R O P T I O N S
Pro Island Hoods
Blower Description
Blower Number
Island Hood Models
1200 CFM Internal
IBLOWER-120INT (804703 – 810317 as of Fall 2007)
All Island Hoods
1100 CFM In-Line
BLOWER-110IL (808332)
All Island Hoods
900 CFM Remote
BLOWER-90REM (801641)
PI363418 / PI423418 / PI543418
1200 CFM Remote
BLOWER-120REM (801642)
All Island Hoods
1500 CFM Remote
BLOWER-150REM (804701)
All Island Hoods
Pro Island Hoods
Model
PI363418
PI423418
PI543418
PI663418
DF304 / R304 / SRT304
600
600
DF366 / R366 / SRT366 / RT366
900
DF364 / R364 / SRT364 / RT364
900
RT362
900
R488 / RT488
1100
DF486 / R486 / SRT486 / RT486
1100
DF484 / R484 / SRT484 / RT484
900
DF606 / R606
1500
DF604
1500
Minimum CFM requirements for Wolf ranges and rangetops. CFM recommendations are based on total Btu/hr output.
Additional CFM may be required for charbroilers, griddles and long duct runs.