beautypg.com

Operations, Shutting down maintenance and care, Troubleshooting – Windsor Recover 7 User Manual

Page 7

background image

English

7

Î

Plug in the main plug.

Î

Turn the machine on and put it into op-
eration.

The vacuum canal (6) is equipped with a
float.
– When the dirt water reaches the highest

permissible level in the container, the
vacuum power is interrupted.

Î

Turn off the machine.

Î

Empty the dirt container.

Î

Empty the dirt container.

Î

Vacuum and wipe the machine inside
and outside.

Î

Place the machine in a dry room and
secure it from unauthorized use.

Warning

First remove the main plug before doing
any job on the vacuum cleaner.

Î

Release and remove the vacuum head.

Î

Turn the vacuum basket by 180° and
keep it aside.

Î

Loosen nut (3).

Î

Remove the cartridge filter (1).

Î

Insert the new cartridge filter (1).

Î

Insert the nut (3) and tighten it.

Î

Insert and lock the vacuum head.

Î

Check cables, plugs, fuse, and socket.

Î

Turn on the machine.

– Float is blocking the vacuum canal.

Operations

Turning on the Machine

Emptying the dirt container

Shutting down

Maintenance and care

Change cartridge filter

Troubleshooting

Vacuum motor does not run

Vaccum motor is running but the

machine is not vacuuming in dust/

dirt