beautypg.com

WhisperKool SS7000 User Manual

Page 27

background image

5. Evaporator blower
not running

Faulty blower motor or broken wire connection.

Call a CERTIFIED HVAC service technician

6. Obstruction to air
flow

Check for obstruction to air flow and repair

7. Anti-frost control not
working

With ice or frost in the evaporator coil, the compressor
should be OFF and the evaporator blower running.
If compressor is running with ice on the coil, call a
certified HVAC service technician.

Humidity in cellar too high

1. Compressor short
cycling

See Compressor Short Cycling Subject (above)

2. Refrigeration not
running properly

Check items above

Call a CERTIFIED HVAC service technician

3. Cellar vapor barrier
not sufficient

Install proper vapor barrier

-27-