beautypg.com

Wiring diagrams, Single stage and multi-stage connections, Single stage (ss 1) – White Rodgers 1F95-0671 User Manual

Page 3: Multi-stage (ms 2)

background image

3

WIRING DIAGRAMS

Figure 2 – Single Stage or Multi-Stage System (No Heat Pump)

with Single Transformer

Single
Stage 1
(SS1)

Multi-
Stage 2
(MS2)

O

Energized Constantly

in

Cool Mode

B

Energized Constantly

in Heat, Off,

Emergency

Mode

No
Output

Cool
Mode
2nd
Stage

Cool Mode
1st Stage

Blower/
Circulator
Fan Energized
on Call for
Cool (and
Heat if
configured
for Electric
Heat)

No Output

Heat Mode
2nd Stage

Heat
Mode
1st Stage

Optional*

24 Volt

(Com-

mon)

24 Volt
(Hot)
Cool

System

Y

G

W/E

C

L

RC

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

24 Volt
(Hot)
Heat

RH

Y2

W2

Jumper

Diagnostic
Indicator
Input
or
System
Malfunction
Switch
Input

Comfort Alert II Module

or Similar System

Diagnostic Module

See Module Instructions

for details

O/B

* Common connection required for diagnostic or malfunction indication.

Figure 3 – Single Stage or Multi-Stage System (No Heat Pump)

with Two Transformers

Single
Stage 1
(SS1)

Multi-
Stage 2
(MS2)

No
Output

Cool
Mode
2nd
Stage

Cool Mode
1st Stage

Blower/
Circulator
Fan Energized
on Call for
Cool (and
Heat if
configured
for Electric
Heat)

No Output

Heat Mode
2nd Stage

Heat
Mode
1st Stage

Optional

24 Volt

(Com-

mon)

Diagnostic
Indicator
(Optional)

24 Volt
(Hot)
Cool

System

Y

G

W/E

C

L

RC

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

24 Volt
(Hot)
Heat

RH

120VAC

Remove Jumper Wire
between RH & RC

HOT

24VAC

NEUTRAL

CLASS II

TRANSFORMER

HEATING

COOLING

Y2

W2

Jumper

O/B

O

Energized Constantly

in

Cool Mode

B

Energized Constantly

in Heat, Off,

Emergency

Mode

Single Stage and Multi-Stage Connections

Refer to equipment manufacturers' instructions for specifi c
system wiring information.
This thermostat is designed to operate a single-transformer
or two-transformer system.
You can confi gure the thermostat for use with the following
systems:

SINGLE STAGE (SS 1)

gas, oil or electric.

MULTI-STAGE (MS 2)

gas, oil or electric.

After wiring, see INSTALLER CONFIGURATION section for
proper thermostat confi guration.

Refer to equipment manufacturers' instructions for specifi c
system wiring information. After wiring, see CONFIGURA-
TION section for proper thermostat confi guration.

Wiring diagrams shown are for typical systems and describe
the thermostat terminal functions.

TERMINAL DESIGNATION DESCRIPTIONS

Terminal Designation Description

O/B ........................................... Changeover valve for heat pump energized constantly in cooling and off/heating
Y2 ............................................ 2nd Stage Compressor
Y

............................................ Compressor

Relay

G

............................................ Fan

Relay

RC ............................................ Power for Cooling

RH ............................................ Power for Heating

C ............................................ Common wire from secondary side of cooling (Optional). Required for fault indication, continuous back-

light operation or remote temperature sensor operation 6 Powered closed 3rd wire for 3-wire zone valve
W/E ........................................... Heat Relay/Emergency Heat Relay (Stage 1) (3rd Stage Heat in HP2)
W2

............................................ 2nd Stage Heat (4th Stage Heat in HP2)

- ............................................ Common (DC) for wired remote temperature sensor

S ............................................ Frequency signal from remote temperature sensor

+ ............................................ Power (DC) to remote temperature sensor

L ............................................ Compressor diagnostic indicator for systems with diagnostic connection typically found on Heat pump

systems or with Copeland's Comfort Alert