beautypg.com

Filter replacement, 5. recording the serial number of a new lamp, Pre l iminar y – Vidikron 140/150 User Manual

Page 95

background image

Maintenance and Troubleshooting

Vision Model 140/150 Owner’s Operating Manual

83

PRE

L

IMINAR

Y

13. Press ENTER to accept the change. This adds the new lamp serial number to the Lamp

History menu and resets the Lamp Hours timer to “0.” Lamp Mode and Lamp Limit
remain as they were for the previous lamp and can be changed at any time.

Figure 5-5. Recording the Serial Number of a New Lamp

Filter Replacement

Whenever you replace the lamp – or more often if the projector is installed in an extremely
dusty environment – you should also replace the two filters located at the front and right
side of the projector.

1.

Loosen the six screws holding right side filter access
panel in place. Then, remove the panel.

2.

Loosen the screw holding front filter access panel in
place. Then, remove the panel.

3.

Pull the filters out of the projector and discard. Do not
reuse filters.

4.

Insert the new filters with the wired side in.

5.

Replace the filter access panels and tighten the
screws to secure them.

Always record the serial number of a new lamp. Do this only if you have
just installed a new lamp. This will ensure that the lamp timer is not reset
on an old lamp and that the number of hours logged on the lamp is
accurate.

Lamp

Hours

147

Lamp

S/N

123456789

1. Lamp

Message

2. Lamp

Limit

1000

3. Lamp

Mode

Power

4. Power

500

5. Intensity

0

6.

RVR 3

7.

Lamp History

8.

Change Lamp

9. Reserved

Lamp Adjust

Note

Front Filter
Access Cover

Right Side Filter

Access Cover