Filter replacement, 5. recording the serial number of a new lamp, Pre l iminar y – Vidikron 140/150 User Manual
Page 95
Maintenance and Troubleshooting
Vision Model 140/150 Owner’s Operating Manual
83
PRE
L
IMINAR
Y
13. Press ENTER to accept the change. This adds the new lamp serial number to the Lamp
History menu and resets the Lamp Hours timer to “0.” Lamp Mode and Lamp Limit
remain as they were for the previous lamp and can be changed at any time.
Figure 5-5. Recording the Serial Number of a New Lamp
Filter Replacement
Whenever you replace the lamp – or more often if the projector is installed in an extremely
dusty environment – you should also replace the two filters located at the front and right
side of the projector.
1.
Loosen the six screws holding right side filter access
panel in place. Then, remove the panel.
2.
Loosen the screw holding front filter access panel in
place. Then, remove the panel.
3.
Pull the filters out of the projector and discard. Do not
reuse filters.
4.
Insert the new filters with the wired side in.
5.
Replace the filter access panels and tighten the
screws to secure them.
Always record the serial number of a new lamp. Do this only if you have
just installed a new lamp. This will ensure that the lamp timer is not reset
on an old lamp and that the number of hours logged on the lamp is
accurate.
Lamp
Hours
147
Lamp
S/N
123456789
1. Lamp
Message
2. Lamp
Limit
1000
3. Lamp
Mode
Power
4. Power
500
5. Intensity
0
6.
RVR 3
7.
Lamp History
8.
Change Lamp
9. Reserved
Lamp Adjust
Note
Front Filter
Access Cover
Right Side Filter
Access Cover