PARAMETER

SELECT

DISPLAY

SCROLL

Left Timer

Press or to enter time.

LED is lit above the left basket

icon. The time value is displayed

in window.

Press and

scroll to next

item.

Right Timer

Press or to enter time.

LED is lit above the right basket

icon. The time value is displayed

in window.

Press and

scroll to next

item.

Set Temperature

Press or to enter

temperature.

The temperature value is

displayed in window.

Press and

scroll to next

item.

Offset
Calibration

For service only

00F

or

-00F

Press and

scroll to next

item.

Melt Options:
Liquid shortening
Solid shortening
No melt

Press or to select melt

option.

CY L (Liquid shortening)

or

CY S (Solid shortening)

or

CY O (No melt)

Press and

scroll to next

item.

Energy

Source

Press or to select

source of heat.

gAS

or

ELEC

Press and

scroll to next

item.

Parameter Lock

Press or to lock or

unlock program entry.

LoC (Unlock Parameter)

or

ULoC (Lock Parameter )

Press and

scroll to next

item.

Fahrenheit or

Celsius

Press or to

select Fahrenheit or Celsius.

F

or

C

Press and

scroll to next

item.

PROGRAMMING

Temperature, time and other parameters must be set before operating. Once these parameters are set,
the fryer can be operated at the touch of a button.

Press

to enter the program mode and scroll through the parameters. If the Parameter Lock feature

is on, LoC is displayed in the window and program entry cannot be accessed. To access the program

mode while LoC is on, press

within 6 seconds of pressing

. To turn the

Parameter Lock feature off, see Program Guide below.

Programming Guide

Once in the program mode, the parameters are displayed in the order listed below. To exit the program

and save changes, press and hold

for approximately 2 seconds.