I n t r o d u c t i o n

This document outlines Chrysalis’ InstallAdvantage (IA) RS-232 protocol specification. This protocol indicates how IA products receive
run-time commands from devices such as Creston Universal Remote Controls.

C o m P o r t S e t u p

Use standard communications settings: Baud Rate: 9600, Data Bits: 8, Parity: None, Stop Bits: 1

I A I N a n d O U T P o r t P i n C o n f i g u r a t i o n

IA serial ports use a standard configuration that allows direct connection to a PC via a FEMALE to MALE serial cable. It uses only
three pins (Transmit, Receive, Ground).

The pin configurations are:

IN:

Pin 2 = Transmit
Pin 3 = Receive
Pin 5 = Ground

OUT:

Pin 2 = Receive
Pin 3 = Transmit
Pin 5 = Ground

R u n t i m e C o m m a n d F o r m a t

Byte Number

Byte Description

Notes

0‘#’

Header Character

1 to 3 or 4

Command and

3 to 4 ASCII characters see formats below

Parameter Data

Case sensitive - CAPS ONLY!

4 or 5

‘$’

Termination Character (required or command is ignored)