Normal call termination – Vizio VS-900 User Manual
Page 12

TOA VS-900 Programmer’s Guide
12
Start of Normal Conversation
Field Name
Length
(Bytes)
Value
Description
Direction
DLE
1
10H
Delimiter
ENQ
1
05H
Enquiry
VS-900 to PC
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
PC to VS-900
DLE
1
10H
Delimiter
STX
1
02H
Start Of Text
Log Data
1
6FH
Log Data
Exchange #
2
30H 31H
Exchange # “01”
Time
(HH:MM:SS)
6
31H 36H 33H 37H 32H
37H
Time: “16:37:27"
Line #1
6
32H 30H 30H 20H 20H
20H
Calling Station # “200”
Line #2
6
31H 30H 35H 20H 20H
20H
Called Station # “105”
Line #3
6
20H 20H 20H 20H 20H
20H
Hold Station # (Blank)
Line #4
6
20H 20H 20H 20H 20H
20H
Not Used (Blank)
Status #
2
31H 30H
“10” (Start of normal
conversation)
DLE
1
10H
Delimiter
ETX
1
03H
End Of Text
BCC
1
74H
Block Check Character
VS-900MF to PC
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
PC to VS-900
DLE
1
10H
Delimiter
EOT
1
04H
End of Transmission
VS-900MF to PC
Normal Call Termination
Field Name
Length
(Bytes)
Value
Description
Direction
DLE
1
10H
Delimiter
ENQ
1
05H
Enquiry
VS-900 to PC
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
PC to VS-900
DLE
1
10H
Delimiter
STX
1
02H
Start Of Text
Log Data
1
6FH
Log Data
Exchange #
2
30H 31H
Exchange # “01”
Time (HH:MM:SS)
6
31H 36H 33H 37H 32H 38H Time: “16:37:28"
Line #1
6
32H 30H 30H 20H 20H 20H Calling Station # “200”
Line #2
6
31H 30H 35H 20H 20H 20H Called Station # “105”
Line #3
6
20H 20H 20H 20H 20H 20H Not Used (Blank)
Line #4
6
20H 20H 20H 20H 20H 20H Not Used (Blank)
Status #
2
33H 32H
“32” (Normal call
termination)
DLE
1
10H
Delimiter
ETX
1
03H
End Of Text
BCC
1
73H
Block Check Character
VS-900MF to PC
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
PC to VS-900
DLE
1
10H
Delimiter
EOT
1
04H
End of Transmission
VS-900MF to PC