Warning, Dewd - cabinet cutout, Cabinet installation – Viking F20022J EN User Manual
Page 2: Important - please read and follow, General information, Electrical connection - use copper conductors only
3
DEWD - CABINET CUTOUT
•To remove drawer assembly, pull warming drawer pan out until fully extended. Slide finger along the right
and left side until you reach the black hand latches (located at the front of the rails). Pull up on both the
right and left latches and pull drawer pan support completely out.
•Slide cavity assembly into cabinet opening.
•Drill (4) pilot holes in cabinet using 1/8” drill bit. Permanently secure the warming drawer using the (4) #8
mounting screws provided.
•Replace drawer assembly.
Model
DEWD170 DEWD100
25 1/4” 28 1/4“
A
(64.1 cm) (71.8 cm)
CABINET INSTALLATION
Cabinet
mounting screws (4) -
#8 x 3/4”
cavity
assy
drawer
assy
9 5/8”
(24.4 cm)
24”
(61.0 cm)
IMPORTANT - PLEASE READ AND FOLLOW
•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please observe all local ordinances. If local codes are applicable, wire in accordance with the National Electrical
Code, ANSI/NFPA 70 - latest edition.
•WARNING - To reduce the risk of electric shock and fire, do not use a flexible power-supply cord with this
appliance.
•The installer should leave these instructions with the consumer who should retain for local inspector’s use
and for future reference.
WARNING!!!
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage,
hertz, wattage, amps, and phase is attached to the product. Wiring the warming drawer with more
voltage than it is rated for may cause severe damage to the thermostat, element, and other components.
Wiring the warming drawer with less voltage than it is rated for may cause significant decrease in
performance. To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical
wiring must be done by qualified people in accordance with all applicable codes and standards, including
fire-rated conditions.
GENERAL INFORMATION
•
THIS UNIT IS NOT TO BE INSTALLED BELOW CABINETS OR WALL MOUNTED.
•When installing this unit directly below other units, only install with Viking built-in products
•Remove warming drawer carefully from carton. Remove all loose packaging and accessories.
•It is the responsibility of the installer to comply with local codes. If no local codes are applicable, wire in
accordance with the National Electrical Code, ANSI/NFPA 70 - latest edition.
•This appliance is not fused. Protect with a proper sized fuse or circuit breaker.
•Line disconnect switch, circuit breaker, or plug/receptacle of power cord connection should be readily accessible
to the operator.
•Ground unit per applicable electrical codes.
•Any installation not matching the specifications discussed in these instructions will void the manufacturer’s
warranty.
ELECTRICAL CONNECTION - USE COPPER CONDUCTORS ONLY.
With the appliance positioned in front of the cabinet opening, connect wire leads extending from the
power supply to the terminal block of the unit. Make sure the colored wires of the terminal block are
connected to the corresponding colored wires extending from the power supply.
2