IMPORTANT:

Vent-free gas log heaters add

moisture to the air. Although this is beneficial,

installing firebox in rooms without enough

ventilation air may cause mildew to form from

too much moisture. See Air for Combustion and

Ventilation, page 6.
IMPORTANT:

Make sure the firebox is level.

If firebox is not level, log set will not work

properly.
Note:

Your Vanguard firebox is designed to be

used in zero clearance installations. Wall or fram-

ing material can be placed directly against any

exterior surface on the rear, sides, or top of your

firebox, except where standoff spacers are inte-

grally attached. If standoff spacers are attached to

your firebox, these spacers can be placed directly

against wall or framing materials.
Use the dimensions shown for rough openings to

create the easiest installation (see Built-In Firebox

Installation, page 14).

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will

ensure safe installation.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 6.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 6).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

INSTALLATION

Continued

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides and Rear

42"

16"

0"

Figure 6 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

Example

*

Mantel Clearances for Built-In
Installation
If placing custom mantel above built-in firebox,

you must meet the minimum allowable clearance

between mantel shelf and top of firebox opening

shown in Figure 8. These are the minimum allowable

mantel clearances for a safe installation. Use larger

clearances wherever possible to minimize the heating

of objects and materials placed on the mantel.

CAUTION: Close screens

before operation of vent-free

gas log heater. Do not allow the

heater to touch or extend beyond

the fireplace screen.

If your installation does not meet the minimum

clearances in Figure 8, you must:
• raise the mantel to an acceptable height,
OR • remove the mantel.

Figure 7 - Minimum Mantel Clearances

for Built-In Installation

For

FB32NCA

and

NLFB32NC

Series

noncirculating,

smooth face

models

For

FB32CA

and

NLFB32C

Series

circulating,

louvered

models only

Supplied
Firebox Hood
Must Be Used
at All Times

Wire-mesh
Screen

Firebox

Mantel Shelf

13" 16" 19" 21"

19" 20" 21" 22"

For FB32NCA and NLFB32NC
Series noncirculating
smooth face models

2

1/2

"

6"

8"

10"

For FB32CA and NLFB32C
Series circulating louvered
models only

Note:
All vertical measurements
are from top of fireplace
opening to bottom of mantel
shelf. All measurements
are in inches.
Facing material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments.

Facing material

(above firebox)

may be of

combustible

material, including

decorative mantel

ornaments.

Note: All vertical measurements

are from top of fireplace opening

to bottom of mantel shelf. All

measurements are in inches.