beautypg.com

Vinotemp WINE-MATE VINO6500SSD User Manual

Page 2

background image

- 1 -

CAUTION:
DO NOT SWITCH ON THE COMPRESSOR IF THE CONDENSING UNIT IS
EQUIPPED WITH A LOW AMBIENT CONDITION KIT UNTIL THE UNIT HAS
BEEN PLUGGED IN FOR 24 HOURS.

2. Valve Operation (Condensing unit)

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 5 ROTALOCK Valve Operation


BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 6 Base Valve Operation

1 – Process & Manometer; 2 – Receiver/Compressor Suction
3 – Liquid/Suction Line; 4 – Pressure Control

Back Position: Process and manometer port closed for normal operation
Front Position
: Connection to liquid or suction line closed
Middle Position: All ports open for evacuation, charge and manometer reading


3. Evaporator Unit

• The WM25-85SFCD evaporator units shall be installed for ceiling mount

with air supply on both sides and air return on the bottom.

• Supply and return air flow from the evaporator unit shall be unobstructed

for at least 1 foot.