beautypg.com

Owner’s manual, Installation, Continued – Vanguard Heating VMH26NR User Manual

Page 17: Optional wall switch - gwms2

background image

17

104325

OWNER’S MANUAL

AUT

O

OFF

ON

W

R

INSTALLATION

Continued

Figure 31 - Connecting Wire Terminals

OPTIONAL WALL SWITCH -
GWMS2

WARNING: Do not connect

this switch to any electrical
source! Electrical shock and/or
fire hazard will occur.

6.

Connect one bare wire end to each ter-
minal (“W” and “R”) of the thermostat
base (see Figure 33).

7.

Install the base onto the wall with the
provided screws.

8.

Move the temperature adjustment back
and forth to insure the bimetal is free
from restrictions.

9.

Replace the cover onto the base. (Upon
installation, the thermostat must be al-
lowed to stabilize at room temperature
for a minimum of 30 minutes for proper
operation).

10. Set switch on heater to Auto position.

11. Set the temperature adjustment to the

desired setting. This thermostat has
been electronically calibrated at the
factory. No adjustment or leveling is
necessary.

1.

Connect one terminal of 25 ft. wire to
bottom contact of switch (see Figure 31).

2.

Connect remaining wire terminal to the
“TH” terminal on the control valve.
Make sure that wire terminals are in
the positions on your unit as pictured
in Figure 31. If wires are not “crossed”
the thermostat will not work.

3.

Route the 25 ft. wire to a convenient
location to mount your wall switch (no
outside walls).

WARNING: Do not connect

the switch to a power source.
Electrical shock and/or fire haz-
ard will occur.

WARNING: Read and follow

installation instructions. Instal-
lation should be done by a quali-
fied installer familiar with low-
voltage wiring procedures.

One
terminal of
25 ft. wire

Switch on Gas
Heater

To Wall
Thermostat
or Switch

To Wall
Thermostat or
Switch

Control
Valve

Figure 32 - Back View of Thermostat Base

Feed wires through
rectangular slots

Figure 33 - Thermostat Base Terminals
"W" and "R"

Terminal "W"

Terminal "R"

IMPORTANT:

The wire may be shortened

but must not be lengthened.

4.

Connect one bare wire end to each of
the terminals of the provided wall
switch.

5.

Install the wall switch and cover in the
wall.