beautypg.com

Vent-free natural gas heater, Installation, Continued – Vanguard Heating VN1800ITB User Manual

Page 8: Installing heater to wall, Thermostat sensing bulb

background image

8

104246

VENT-FREE NATURAL GAS HEATER

®

Marking Screw Locations

1.

Tape mounting bracket to wall where
heater will be located. Make sure
mounting bracket is level.

Model VN2550ITB

Model VN1800ITB

Figure 8 - Mounting Bracket Clearances

2.

Mark screw locations on wall (see Fig-
ure 8).

Note:

Only mark last hole on each end

of mounting bracket. Insert mounting
screws through these holes only.

3.

Remove tape and mounting bracket
from wall.

18 3/4"

Min.

13"

Min.

16"

Adjoining Wall

Only Insert Mounting

Screws Through Last

Hole On Each End

Floor

WARNING: Maintain minimum

clearances shown in Figure 8. If
you can, provide greater clear-
ances from floor and joining wall.

Methods For Attaching
Mounting Bracket To Wall

Only use last hole on each end of mounting
bracket to attach bracket to wall. These two
holes are 16 inches apart from their centers.
Attach mounting bracket to wall in one of
two ways.

1.

Attaching to wall stud

2.

Attaching to wall anchor

Attaching To Wall Stud:

This method pro-

vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.

INSTALLING HEATER TO
WALL

Mounting Bracket

Locate mounting bracket in heater carton.
Remove mounting bracket from heater carton.

Figure 7 - Removing Front Panel Of Heater

Removing Front Panel Of Heater

1.

Remove two screws near bottom cor-
ners of front panel.

2.

Lift straight up on grill guard until it stops.
Grill guard will slide up about 1/4".

3.

Pull bottom of front panel forward, then
down.

Figure 6 - Mounting Bracket

INSTALLATION

Continued

Figure 5 - Attaching Thermostat Sensing
Bulb

Thermostat
Sensing
Bulb

THERMOSTAT SENSING
BULB

The thermostat sensing bulb has been placed
inside the heater for protection during shipping.

Locating Thermostat Sensing
Bulb

1.

Remove front panel of heater (see Fig-
ure 7).

2.

Locate thermostat sensing bulb just
under the burner assembly.

IMPORTANT:

Attach thermostat sensing bulb

to the back of heater for proper operation.

Attaching Thermostat Sensing
Bulb

1.

Remove thermostat sensing bulb from
holders inside heater. Route through
slot opening in bottom of heater.

2.

Place clamp on thermostat sensing bulb
as shown in Figure 5. Clamp is pro-
vided in hardware package.

3.

Snap clamp into upper mounting hole
as shown in Figure 5. Mounting hole is
located on lower left edge on back of
heater. Make sure the thermostat sens-
ing bulb is pointing up.

Attaching To Wall Anchor:

This method

allows you to attach mounting bracket to
hollow walls (wall areas between studs) or
to solid walls (concrete or masonry).

Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.

Clamp

16"

18 3/4"

Min.

9 1/4"

Min.

Adjoining Wall

Only Insert Mounting

Screws Through Last

Hole On Each End

Floor

This manual is related to the following products: