Technical information cont – Verona WALL HUNG GAS BOILER User Manual
Page 10

2.Technical Information Cont.
ENERGY CAPACITY
Nominal heat input
(0/2000ft)
MBH 122.8
Nominal heat input
(2000/4500ft)
MBH 116.7
Minimum heat input
MBH
49.5
Maximum useful output
(0/2000ft)
MBH 100.7
Maximum useful output
(2000/4500ft)
MBH 95.9
Minimum useful output
MBH
37.0
GAS SUPPLY PRESSURE
Gas
Normal
Min
Max
Natural inwc 7.0 3.5 10.5
Propane
inwc
11.0 8.0 12.0
GAS PRESSURE AT BURNER
Gas Min
Max
Ignition
Natural inwc 0.8 5.3 2.4
Propane inwc 1.4
9.0
5.2
FLUE DESIGN
Minimum Venturi pressure inwc
0.64
Flue pipe diameter
Coaxial in
2.25/4
3.25/5
Twin split pipes
in
3.25/3.25
Nominal heat flow rate
(0/2000ft)
MBH 122.8
Nominal heat flow rate
(2000/4500ft)
MBH 116.7
Min Exhaust temperature
°F
262
Max Exhaust temperature
°F
324
INJECTORS No. Size
Natural 14
130
Propane 14
89
GAS FLOW RATE
Gas Min
Max
Natural ft³/h 48.7 121.1
Propane
lb/h 2.23 5.55
ELECTRICAL
Voltage V
120
Frequency Hz
60
Current A
<
1.6
Power consumption
W
176
FLUE GAS FIGURES
Gas Min
Max
CO
2
2.5% 7.2%
O
2
16.5% 8.1%
RIVA HEAT ONLY MANUAL - REV A
10