Door Alignment Check and Adjustment
IMPORTANT
IMPORTANT
Properly aligned, the door’s gasket should be firmly
in contact with the cabinet all the way around the
door (no gaps). Carefully examine the door’s gasket
to assure that it is firmly in contact with the
cabinet. Also make sure the door gasket is not
pinched on the hinge side of the door.
Figure 15
1. Loosen (do not remove) top (Figure 15) and bottom
hinge screws.
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
Door Reversal
Depending upon the location of the unit, it may be
desirable to change the side on which the door is
mounted.
To reverse the door mounting, perform the following:
Figure 16
1. Remove grille (one screw) (Figure 16, 1).
Figure 17
2. Remove top hinge from cabinet (three screws) (Figure
17). Hold door to keep it from falling.
3. Lift the door off the bottom hinge.
Figure 18
4. Remove bottom hinge from cabinet (two screws)
(Figure 18).
Figure 19