Maintenance

Preventive Maintenance:

The following system checks should be made every six to twelve months:

Check the Standing Wave Ratio(SWR)
Inspect the tightness of all electrical connections.
Inspect the antenna coaxial cable for wear or breaks on the shielding
Inspect the tightness of all screws and other mounting hardware.

Troubleshooting:

Should the unit malfunction or perform poorly, follow these procedures;

If the transceiver is completely inoperative…

Check the power cord and fuse.

If there is trouble with receiving…

Check the VOLUME control setting. Be sure the SQUELCH is adjusted properly. Possibly the radio is over

squelched.

If there is trouble with transmitting…

Check that the transmission line (coaxial cable) is securely connected to the ANTENNA connector.
Check that the antenna is fully extended for proper operation.
Check that all transmission line (coaxial cable) connections are secure and free of corrosion.

Memory Backup:

A built-in capacitor protects the channels stored in the UH012 memory after the

DC power cable is disconnected.

Turn the Rotary Channel Selector to select the

Priority Channel you prefer.
Press and hold for 2 seconds to store

the new setting.

Programming the Instant Priority Channel

Recalling the Instant Channel

Momentarily press at any time to return to the Instant Channel.