SECTION 8
Troubleshooting
Engraving Quality
Problem
Possible Cause
Possible Solution
“Fuzzy” looking raster engraving or
small text appears like a “double
image”
•
Dirty laser system
•
Graphic, graphic software, graphic software
setup, color palette, monitor display colors, or
driver settings have changed
•
Speed to fast for the material
•
Out of focus
•
System needs tuning
Worn X-axis belt and/or drive gear
Laser Tube is faulty
•
Clean all optics, rails, bearings and belts
•
Check to see what has changed. Use
“Software Setup Guide” to properly setup the
graphics software to work correctly with the
laser system. Check driver settings.
•
Slow down engraving speed
•
Re-focus
•
Run “Tuning” feature in printer driver version
4.17 and higher
•
Replace belt and/or drive gear, and run
“Tuning” feature
•
Replace laser tube
Fine detail is missing such as the
serif’s of characters or thin lines of
script fonts when raster engraving
•
Speed too fast for the material
•
Out of focus
•
System needs tuning
•
Laser spot size too big
•
Slow down engraving speed
•
Re-focus
•
Run “Tuning” feature in printer driver version
4.17 and higher
•
Use shorter focal length lens
Vertical or diagonal background
pattern
present
when
raster
engraving large areas and/or large
amounts of material
•
Dirty laser system
•
Slight pattern is normal
If the pattern is excessive:
•
Loose motion system components
•
Worn or damaged X-axis bearings
•
Worn or damaged X-axis rail
•
Clean all optics, rails, bearings and belts
•
Don’t remove so much material or try
engraving shallower or deeper. Try changing
PPI and or DPI
•
Use a 50% black fill to “halftone” the
background which can hide the pattern
•
Check X-axis bearings, belt, optics
•
Replace X-axis bearings
•
Replace X-axis arm
Horizontal
background
pattern
present when raster engraving large
areas and/or large amounts of
material
•
Dirty laser system
•
Slight pattern is normal
If the pattern is excessive:
•
Laser is too cold or hot
•
Laser tube is faulty
•
Clean all optics, rails, bearings and belts
•
Don’t remove so much material or try
engraving shallower or deeper. Try changing
PPI and or DPI
•
Use a 50% black fill to “halftone” the
background which can hide the pattern
•
Check and/or clean filters
•
Make sure ambient temperature is within
specifications
•
Replace laser tube
Engraving disappears, becomes
“lighter”, or appears “choppy” when
raster engraving within ½ inch of Y-
axis ruler
•
Normal condition. The laser system needs to
accelerate and decelerate within this area
•
Move graphic and/or material to the right,
outside of this area
•
Slowing the raster speed down reduces the
effect