Natural gas steam boilers – Utica PEG-C User Manual

Page 28

background image

FRONT

VIEW

LEFT

SIDE

VIEW

RIGHT

SIDE

VIEW

3741801

PAGE 26

REV: 15, July 2003

R

A

TINGS

,

D

A

T

A

,

AND

DIMENSIONS

NATURAL

GAS

STEAM

BOILERS

*A.G.A

Heating

Net

I=B=R**

G

as

Dimensions

WATER

CONTENT

Annual

Fuel

Boiler

Input

Capacity

Steam

R

ating

Inlet

(GALLON CAPACITY)

Utilization

Efficiency

Number

B

tu/Hr.

Btu/Hr.

Btu/Hr.

Sq.

Ft.

Size

A

B

C

D

E

F

G

To

Water

To

LWCO

(AFUE)

&

Damper

&

Damper

Line

Line

Elect

Ign

Std.

P

ilot

PEG112C

112,500

90,000

67,500

28

1

1/2

14.1/4

27.5/8

24.1/8

5

3.1/2

6

44.3/4

4.8

3.0

81.0

78

PEG150C

150,000

120,000

90,000

37

5

1/2

17.1/8

28.5/8

24.5/8

6

4

6.1/2

45.1/4

6.0

3.7

81.0

78

PEG187C

187,000

151,000

113,300

47

2

1/2

20

29.5/8

25.1/8

7

4.1/2

7

45.3/4

7.0

4.4

81.0

78

PEG225C

225,000

181,000

135,800

55

6

3/4

22.13/16

30.5/8

25.5/8

8

5

8

46.3/4

8.4

5.0

81.0

78

PEG262C

262,500

212,000

159,000

66

3

3/4

25.5/8

30.5/8

25.5/8

8

5

8

46.3/4

9.5

5.8

81.0

78

PEG300C

299,

999

243,000

182,300

76

0

3/4

28.1/8

31.5/8

26.1/8

95.1/2

10

48.3/4

10.7

6.4

81.0

78

NOTE:

For

altitudes

above

2,000

ft.

ratings

should

be

reduced

at

the

rate

of

4%

for

each

1,000

ft.

above

sea

level,

The

MEA

number

for

the

PEG

series

is

17-79.

Electrical

service

to

be

120

Volts,

15

Amps,

60

Hz.

**For

equivalent

square

feet

of

radiation,

divide

I=B=R

output

by

240.

STANDARD

EQUIPMENT:

C

rafted

Boiler,

Drafthood,

Low

Water

Cut-off

(Probe

Type),

Deluxe

Jacket,

Wiring,

Automatic

Vent

Damper,

Ported

Stainless

Stee

l Burners,

Blocked

Vent

and

Roll-Out

Safety

Switches,

Gas

Valve,

Pilot,

Pressure

High

Limit

Control,

2-2"

Supply

Tapping-L.H.

Plugged,

2-2

"

Return

Tappings-L.H.

Plugged.

Packed

in

Separate

Carton:Pop

Safety

Valve

and

Boiler

Drain.

OPTIONAL

EQUIPMENT:

Electronic

water

feeder

The

Ratings

marked

“Net

I=B=R”

indicate

the

amount

of

equivalent

direct

cast

iron

radiation

each

boiler

will

take

care

of

under

normal

conditions

and

thermostatic

control.

The

Net

I=B=R

Steam

Ratings

shown

are

based

on

a

piping

and

pickup

allowance

of

1.333.

Proper

allowance

has

been

made

for

piping

an

d

pickup

in

accordance

with

the

factors

shown

in

the

I=B=R

Standard

as

published

by

The

Hydronics

Institute.

Selection

of

boiler

size

should

be

based

upon

Net

BTU

per

Hour

of

the

connected

radiation

and

piping.

The

manufacturer

should

be

consulted

before

selecting

a

boiler

for

installations

having

unusual

piping

and

pickup

requirements.

In

line

with

it's

policy

of

product

improvement,

Utica

Boilers

reserves

the

right

to

make

changes

without

notice.