•DRAWINGS FOR ILLUSTRATION PURPOSES ONLY•

ALTERNATIVE PARALLEL INSTALLATION WIRING DIAGRAM

-

FIG. 14

TO GAS/OIL/ELECTRIC

TRANSFORMER

HOTBLAST

COMBINATION CONTROL

LIMIT

FAN

JUMPER IN

H

H

POWER

SUPPLY

GAS/OIL/ELECTRIC

POWER SUPPLY

JUNCTION BOX

CENTRAL

FURNACE

BLOWER

MOTOR

WOOD

FURNACE

BLOWER

MOTOR

CAUTION!

DO NOT CONNECT

PLENUM FAN CONTROL

SWITCH ACROSS FURNACE

LIMIT CONTROL.

This unit is certified for parallel installation with exitsting