ALTERNATIVE PARALLEL INSTALLATION WIRING DIAGRAM
-
FIG. 14
TO GAS/OIL/ELECTRIC
TRANSFORMER
HOTBLAST
COMBINATION CONTROL
LIMIT
FAN
JUMPER IN
H
H
POWER
SUPPLY
GAS/OIL/ELECTRIC
POWER SUPPLY
JUNCTION BOX
CENTRAL
FURNACE
BLOWER
MOTOR
WOOD
FURNACE
BLOWER
MOTOR
CAUTION!
DO NOT CONNECT
PLENUM FAN CONTROL
SWITCH ACROSS FURNACE
LIMIT CONTROL.
This unit is certified for parallel installation with exitsting