Unibrain 501 User Manual
Page 13

Unibrain Fire-i 501/511/601/701/702/810 Operation Manual
Page 5
Trigger (Fire-i 701/702/810):
Parameter Min
Typical
Max
I
7 mA
10 mA
20 mA
Ri -
270
Ω
-
Vd -
1.08
V
-
Rising trigger delay
2.24 us
3.34 us
3.36 us
Falling trigger delay
2.62 us
3.61 us
3.64 us
Strobe (Fire-i 701/702/810):
Strobe Power
Strobe falling delay
Strobe rising delay
5 V
26.8 us
2.16 us
12 V
7.6 us
2.8 us
24 V
3.6 us
3.4 us