10

ADA24

ADA SERIES

Door Alignment Check and Adjustment

IMPORTANT

IMPORTANT

Properly aligned, the door’s gasket should be firmly
in contact with the cabinet all the way around the
door (no gaps). Carefully examine the door’s gasket
to assure that it is firmly in contact with the
cabinet. Also make sure the door gasket is not
pinched on the hinge side of the door.

Figure 12

1. Loosen (do not remove) top (Figure 12) and bottom

hinge screws.

2. Align door squarely with cabinet.

3. Make sure gasket is firmly in contact with cabinet all

the way around the door (no gaps).

4. Tighten bottom hinge screws.

5. Tighten top hinge screws.

Door Reversal

Black or white unit doors may be left- or right-hand
opening. Depending upon the location of the unit, it may
be desirable to change the side on which the door is
mounted.

6.

Black or White Model

To reverse the door, perform the following:

1. Remove the grille (two screws).

Figure 13

2. Remove top hinge from cabinet (four screws) (Figure

13). Hold door to keep it from falling.

3. Lift the door off the bottom hinge.

Figure 14

4. Remove four plastic plugs (Figure 14) in hinge holes,

top of cabinet, opposite side. Be careful not to scratch
cabinet.

ULIN_0143_A

ULIN_0104_A