OSD Factory Default Settings
The factory default settings are as follows:
Setting
Default
OSD Hotkey
[Scroll Lock] [Scroll Lock]
Port ID Display Position
Upper Left Corner
Port ID Display Duration
3 Seconds
Port ID Display Mode
The Port Number plus the Port Name
Scan Duration
5 Seconds
Scan/Skip Mode
All
Screen Blanker
0 (Disabled)
Logout Timeout
0 (Disabled)
Accessible Ports
F (Full) for all users on all ports
Beeper Y (Activated)
24
To perform a firmware upgrade recovery, do the following:
1) Slide the Firmware Upgrade Recovery Switch (see page 7) to the Recover position.
2) Power off and restart the switch according to the instructions given in the Powering Off and
Restarting section (page 11).
3) Slide the Firmware Upgrade Recovery Switch back to the Normal position.
4) Repeat Step 2.
Note: If one of the slave units fails to upgrade successfully, unchain it from the installation and perform
the recovery and upgrade operation independently. After it has been successfully upgraded, plug it back
into the chain.
Appendix A
Computer Connection Table
The following tables indicate the relationship between the number of Tripp Lite KVMs and the number
of computers that they control:
KVM
CPUs
KVM
CPUs
KVM
CPUs
KVM
CPUs
1 x A
1-16
A + 8B
129-144
A + 16B
257-272
A + 24B
385-400
A +B
17-32
A + 9B
145-160
A + 17B
273-288
A + 25B
401-416
A + 2B
33-48
A + 10B
161-176
A + 18B
289-304
A + 26B
417-432
A + 3B
49-64
A + 11B
177-192
A + 19B
305-320
A + 27B
433-448
A + 4B
65-80
A + 12B
193-208
A + 20B
321-336
A + 28B
449-464
A + 5B
81-96
A + 13B
209-224
A + 21B
337-352
A + 29B
465-480
A + 6B
97- 112
A + 14B
225-240
A + 22B
353-368
A + 30B
481-496
A + 7B
113-128
A + 15B
241-256
A + 23B
369-384
A + 31B
497-512
A = B020-016, B020-016-17, B022-016; B = B022-016
200603055 93-2469 KVM Switch Update.qxd 3/16/2006 1:08 PM Page 24