Notes: 1) All timing measurement switching points (low to high and high to low) shall be taken at 1.5 V.

2) All signal transitions for a timing parameter shall be measured at the connector specified in the

measurement location column. For example, in the case of tRFS, both STROBE and –DMARDY
transitions are measured at the sender connector.

3) The parameter tCYC shall be measured at the recipient’s connector farthest from the sender.
4)The parameter tLI shall be measured at the connector of the sender or recipient that is responding

to an incoming transition from the recipient or sender respectively. Both the incoming signal and the
outgoing response shall be measured at the same connector.

5)The parameter tAZ shall be measured at the connector of the sender or recipient that is driving the

bus but must release the bus the allow for a bus turnaround.