1 descriptions, Bcs ii simplex repeater, Specifications – Telect BCS II User Manual
Page 5: Descriptions, Bcs ii s
![background image](/manuals/215172/5/background.png)
117209-1 A0
1-1
1
Descriptions
BCS II S
IMPLEX
R
EPEATER
The Broadband Connectivity System II (BCS II) Simplex Repeater (part
# 710-3201-0002) regenerates DS3, E3, and STS-1 signals to allow in-
creased separation of network elements and provides full DSX function-
ality. The module installs in any vertical BCS II chassis or in the Vector
chassis and is always installed in pairs.
Features
•
Full signal regeneration to equal level point on each circuit
•
Mini-WECO monitor and I/O jacks
•
Alarm and tracer lamp LEDs
•
Full DSX functionality, including patching, monitoring and loop-
backs
S
PECIFICATIONS
Electrical
Monitor Level: 20 dB + 1.5 dB below signal level
Return Loss: < -24 dB at DS3 signal rate
Impedance: 75
Ω (+/- 5%)
Power
Battery Input: A and B redundant, -42 to -58 Vdc
Input Current: 35 mA nominal @ 48V
Internal Fuse: 1/4 amp, not field replaceable