beautypg.com

General data, Tuy-r9v product specifications 1 – Trane XV 90 User Manual

Page 6

background image

6

Pub. No. 22-1682-05-0802 (EN)

TUY-R9V PRODUCT SPECIFICATIONS1

MODEL

RATINGS2
1st Stage Input BTUH

1st Stage Capacity BTUH (ICS)3

2nd Stage Input BTUH

2nd Stage Capacity BTUH (ICS)3

AFUE (ICS)
Temp. Rise (Min.-Max.) °F.

BLOWER DRIVE
Dia.-Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts/Ph/Hz

COMBUSTION FAN - TYPE
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
FL Amps

FILTER — Furnished?
Type Recommended
Filter (No.-Size-Thk.)

VENT — Size (In.)

HEAT EXCHANGER
Type -Fired

-Unfired

Gauge (Fired)

ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size

GAS VALVE

DIRECT IGNITION DEVICE
Type

BURNERS — Type
Number

POWER CONN. — V/Ph/Hz4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DUCT CONN.

DIMENSIONS
Crated (In.)
Uncrated

WEIGHT
Shipping (Lbs.)/Net (Lbs.)

TUY080R9V3V

52000
49000
80000
73000

92.5

35 - 65

DIRECT

10 x 8

1

VARIABLE

SEE FAN PERF. TABLE

1/2

VARIABLE

115/1/60

CENTRIFUGAL

DIRECT - VARIABLE

1/15 - 5000

115/1/60

1.1

YES

HIGH VELOCITY

1 X 17 X 25 X 1

2 ROUND

ALUMINIZED STEEL TYPE 1

20

4 - 45
4 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITER

IN-SHOT

4

115/1/60

8.4

15

0.50

SEE OUTLINE DRAWING

H X W X D

41-3/4 X 19-1/2 X 30-1/2

SEE OUTLINE DRAWING

158/148

TUY060R9V3V

39000
37000
60000
56000

93.0

35 - 65

DIRECT

10 x 8

1

VARIABLE

SEE FAN PERF. TABLE

1/2

VARIABLE

115/1/60

CENTRIFUGAL

DIRECT - VARIABLE

1/15 - 5000

115/1/60

1.1

YES

HIGH VELOCITY

1 X 17 X 25 X 1

2 ROUND

ALUMINIZED STEEL TYPE 1

20

3 - 45
3 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITER

IN-SHOT

3

115/1/60

8.4

15

0.50

SEE OUTLINE DRAWING

H X W X D

41-3/4 X 19-1/2 X 30-1/2

SEE OUTLINE DRAWING

158/146

TUY100R9V4V

65000
62000

100000

93000

93.0

35 - 65

DIRECT

10 x 10

1

VARIABLE

SEE FAN PERF. TABLE

1

VARIABLE

115/1/60

CENTRIFUGAL

DIRECT - VARIABLE

1/15 - 5000

115/1/60

1.1

YES

HIGH VELOCITY

1 - 20 X 25 X 1

3 ROUND

ALUMINIZED STEEL TYPE 1

20

5 - 45
5 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITER

IN-SHOT

5

115/1/60

11.4

15

0.50

SEE OUTLINE DRAWING

H X W X D

41-3/4 X 23 X 30-1/2

SEE OUTLINE DRAWING

171/160

TUY120R9V5V

78000
74000

120000
112000

92.5

40 - 70

DIRECT

10 x 10

1

VARIABLE

SEE FAN PERF. TABLE

1

VARIABLE

115/1/60

CENTRIFUGAL

DIRECT - VARIABLE

1/25 - 5000

115/1/60

1.1

YES

HIGH VELOCITY

1 - 24 X 25 X 1

3 ROUND

ALUMINIZED STEEL TYPE 1

20

6 - 45
6 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITER

IN-SHOT

6

115/1/60

11.4

15

0.50

SEE OUTLINE DRAWING

H X W X D

41-3/4 X 26-1/2 X 30-1/2

SEE OUTLINE DRAWING

205/193

1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above

input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.

3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

General
Data