General data, Tuy-r9v product specifications 1 – Trane XV 90 User Manual
Page 6
6
Pub. No. 22-1682-05-0802 (EN)
TUY-R9V PRODUCT SPECIFICATIONS1
MODEL
RATINGS2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)3
AFUE (ICS)
Temp. Rise (Min.-Max.) °F.
BLOWER DRIVE
Dia.-Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts/Ph/Hz
COMBUSTION FAN - TYPE
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
FL Amps
FILTER — Furnished?
Type Recommended
Filter (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
DIRECT IGNITION DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V/Ph/Hz4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
TUY080R9V3V
52000
49000
80000
73000
92.5
35 - 65
DIRECT
10 x 8
1
VARIABLE
SEE FAN PERF. TABLE
1/2
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 X 17 X 25 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 45
4 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
4
115/1/60
8.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
158/148
TUY060R9V3V
39000
37000
60000
56000
93.0
35 - 65
DIRECT
10 x 8
1
VARIABLE
SEE FAN PERF. TABLE
1/2
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 X 17 X 25 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
3 - 45
3 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
3
115/1/60
8.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
158/146
TUY100R9V4V
65000
62000
100000
93000
93.0
35 - 65
DIRECT
10 x 10
1
VARIABLE
SEE FAN PERF. TABLE
1
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 - 20 X 25 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
5
115/1/60
11.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
171/160
TUY120R9V5V
78000
74000
120000
112000
92.5
40 - 70
DIRECT
10 x 10
1
VARIABLE
SEE FAN PERF. TABLE
1
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/25 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 - 24 X 25 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 45
6 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
6
115/1/60
11.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
205/193
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above
input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
General
Data