14
Table 2.1 PM104 Pin Number and I/O Functions
IC3 PIN#
PM104 Microcontroller Description (IC3)
HE104 Function or Connection
Battery Charger Function
1
PM104 Supply Voltage
HE104 Supply Voltage
2
Common
Common
3
PC0 (PC out)
Connector CN4-3
4
PCI (Pc in)
Connector CN4-4
5
plus5V input/output
No connection
6
Reset
No connection
7
P0 (Input/Output Pin 0)
Input Voltage Status
8
P1 (Input/Output Pin 1)
HE104 On/Off Control
HE104 On/Off control
9
P2 (Input/Output Pin 2)
Connector CN6-8
Analog/Digital Chip Select
10
P3 (Input/Output Pin 3)*
Int2, Connector CN6-7*
Spare* Input/Output
11
P4 (Input/Output Pin 4)
Connector CN6-6
Data Input/Output Line
12
P5 (Input/Output Pin 5)
Connector CN605
Data Clock
13
P6 (Input/Output Pin 6)*
Int1, Connector CN6-4*
Spare* Input/Output
14
P7 (Input/Output Pin 7)
Connector CN6-3
Analog Current Limit
*If Interrupt function is not used, this PM104 line can be used for general purpose Input/Output.
2.9 Low Input Alarm
This output signals the Power Management circuit (PM104) or external circuitry that main input power
has failed. The Low Input Alarm signal has a 100K current limiting resistor in a series.
If the PM104 is not installed, then external circuitry can access the Low Input Alarm output on
connector IC3-7.