1. Introduction
2. Installation and Setup
1.1 Product Features
2.1 System Requirements
2.2 Communications Setup
1.2 Package Contents
The RELAYIOCARD is a programmable UPS management device featuring:
6 programmable relay output contacts
•
Configurable normal open or normal close for each relay contact
•
Configurable UPS shutdown delay time
•
Configurable input signal to shutdown UPS or test battery
•
The RELAYIOCARD allows you to:
Monitor UPS status and events
•
Perform remote system shutdowns and battery tests
•
The RELAYIOCARD supports all Tripp Lite SmartOnline™ UPS Systems and select SmartPro™ UPS Systems, including SMART1050SLT,
SMART1500SLT, SMART2200RMXL2U, SMX1050SLT, SMX1500SLT, SMART3000SLT, SMART2200SLT, SM2200RMNAFTA, SMART2600RM2U,
SMART3000RM2U, SMART1500CRMXL, SMART1500SLTXL, SMART750XLa, SMX3000XLRT2U and SMX2200XLRT2U. Supported systems must
run a UPS protocol of 3008 or above.
To determine your UPS protocol:
Open Tripp Lite PowerAlert software.
1.
Click on the “Misc” button on the main screen of the PowerAlert console.
2.
View the protocol variable.
3.
Connect Tx to pin2, Rx to pin 3 and GND-C to pin5 of RS-232 DBP port.
1.
In the Windows environment, launch the Hyper Terminal program, then open the specified COM port.
2.
Set the following properties – Baud rate: 2400, Data Bits: 8, Parity: None, Stop Bit: 1, Flow Control: None.
3.
This Package Contains:
RELAYIOCARD
•
Configuration Cable
•
Faceplates
•
Owner’s Manual
•
PROGRAMMABLE RELAY I/O CARD
USER MANUAL
PRESENTATION
FEATURES
This relay I/O card is an UPS management
product with 6 relay output contacts for monitoring
the status and 1 input contact as a shutdown UPS
or a battery test command.
Features:
z
Monitor UPS events.
z
6 programmable relay output contacts.
z
Configurable normal open or normal close for
each relay contact.
z
Configurable UPS shutdown delay time.
z
Configurable input signal as shutdown UPS or
battery test.
z
Has the ability to protect up to 6 computers
unattended shutdown gracefully.
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
Size
130 x 60 mm
Weight
200 g
Operating Temperature 0 ~ 40q C
Operating Humidity
10 ~ 80 %
Power Input
8 ~ 20V DC
Power Consumption
1.2 Watts
OUTPUT CONTACT RATING
Maximum
DC Voltage DC Current
Relay
R1~R6
24 V
1A
INPUT RATING
Maximum
DC Voltage DC Current
Input
24 V
10 mA
APPLICATION EXAMPLE
In this case we’ll use the default settings, please
set SW1 and SW2 to the OFF position. Apply
12VDC to
Common contact and connect the
lamps to
R1~R6 terminals. Install a push button
from the Common contact to the input terminal.
Press the button for at least 3 seconds to
shutdown the UPS remotely.
Common
GND-R
R1
R2
R3
R4
R5
Input
+12V
Summary Alarm
Power Fail
Battery Low
On Bypass
Overload
Shutdown UPS
R6
Over Temperature
INTERNAL CIRCUIT
R1
R2
R3
R4
R5
Common
GND-R
Input
+5V
CPU Pin
R6
OUTLINE
GND-R
Common
R1
R2
R3
R4
R5
R6
Input
Tx
Rx
GND-C
SW1
SW2
I/O PINOUT
GND-R: Ground for relays
Common: 12~24VDC
Default Alarm Event
R1
Summary Alarm
R2
Power Fail
R3
Battery Low
R4
On Bypass
R5
Overload
R6
Over Temperature
Input: Remote shutdown or battery test
Tx: Transmit to PC, connect to sub9-pin2
Rx: Receive from PC, connect to sub9-pin3
GND-C: Ground for configuration Tx and Rx pins
OFF (Default)
ON
SW1 Normal open
for default settings
Normal close
for default settings
SW2 Default settings
Customized settings
PROGRAMMABLE CONTACTS
COMMUNICATION SETUP
1. Connect
Tx to pin2, Rx to pin3 and GND-C to
pin5 of PC RS232 port.
2. In the Windows environment, launch the
Hyper- Terminal program then open the
specified COM port.
3. Set the following properties:
Baud rate:
2400, Data Bits: 8, Parity: None
Stop Bit:
1, Flow Control: None
CONFIGURATION
1. Press
programmable relay card.
_8365HOD\&DUG_
)LUPZDUH9HUVLRQ5HOD\&DUG9
>@&XVWRPL]H2XWSXW5HOD\
>@&RQILJXUH,QSXW6LJQDO
>@&XVWRPL]H1RUPDO2SHQRU1RUPDO&ORVH
>@4XLW
3OHDVH(QWHU 2. Press ‘1’ to configure the alarm event for R1~R6. Contacts R1~R6 can be configured for different power events. 3OHDVH(QWHU Once the configuration is complete SW2 MUST be switched to the ON position to apply the new settings, switch SW2 back to the OFF position to reset to the default settings. 3. Press ‘2’ to configure the Input signal. 3OHDVH(QWHU In this menu, the input signal can be redefined as shutdown UPS or battery test signal. Meanwhile, the UPS shutdown delay time is also adjustable to a maximum of 9999 seconds. 4. Press ‘3’ to configure the normal open or normal close for each relay. 3OHDVH(QWHU Once the configuration is complete SW2 MUST be switched to the ON position to apply the new settings. Switch SW2 back to the OFF position to reset to the default settings. 5. Press ‘0’ to quit this configuration session. The system would prompt you to save or not. Press ‘Y’ to save your settings, ‘N’ to ignore. POWER OPTION IN WIN 2000/XP This relay card has the ability to provide UPS signals for Windows NT4/2000/XP/2003. First connect the RS232 port on the PC to the relay card as shown: Then open the power option from control panel and click on the UPS tab to setup the signals polarity, select Positive for Power Fail, Low Battery and UPS Shutdown. Since the R1~R6 contacts are programmable, the output contacts can be configured for 3 computers with 2 signals (power fail and low battery) or 6 computers with one signal (power fail or low battery). Note: All of the computers must have the same earth ground potential. Connect all of the computers input power to the same UPS. Common GND-R R1 R2 R3 R4 R5 Input Power Fail R6 Battery Low RTS pin7 GND pin5 CTS pin8 DCD pin1 DTR pin4 Shutdown UPS 200805102 93-2815.indd 2 7/15/2008 9:19:00 AM
_&XVWRPL]H2XWSXW5HOD\_
5HOD\6HOHFWHG(YHQW
>@5HOD\6XPPDU\$ODUP
>@5HOD\3RZHU)DLO
>@5HOD\%DWWHU\/RZ
>@5HOD\2Q%\SDVV
>@5HOD\2YHUORDG
>@5HOD\2YHU7HPSHUDWXUH
>@%DFN7R3UHYLRXV0HQX
_&RQILJXUH,QSXW6LJQDO_
>@$FWDV6KXWGRZQRU7HVW6KXWGRZQ
>@,QSXW6LJQDO&RQILUP6HFRQGV
>@'HOD\%HIRUH6KXWGRZQ6HFRQGV
>@%DFN7R3UHYLRXV0HQX
_&XVWRPL]H2XWSXW5HOD\_
5HOD\6HOHFWHG(YHQW
>@5HOD\1RUPDO&ORVH
>@5HOD\ 1RUPDO2SHQ
>@5HOD\ 1RUPDO&ORVH
>@5HOD\1RUPDO2SHQ
>@5HOD\1RUPDO&ORVH
>@5HOD\1RUPDO2SHQ
>@%DFN7R3UHYLRXV0HQX