If the display malfunctions proceed as follows:
1. Loosen the 6 fastening screws in the top of the
user interface (FIGURE 7).
2. Carefully lift the top and turn it so that the wire joint is exposed.
Detach the joint by pressing the lever towards the wire and pull
the wire connector out (FIGURE 8). Be careful not to let the
wire drop inside the tube.
3. If the bottom of the user interface is damaged, remove it by
unscrewing the 2 fastening screws at the bottom (FIGURE 9).
Defective parts should be sent to your Tunturi dealer.
4. Ensure that the meter wire is securely locked in place when
replacing the top of the interface by gently pulling on the joint.
If you require spare parts for your equipment, please contact your dealer
with the model, equipment serial no. and spare part number of the
required part. There is a spare part list at the back of this manual.
TECHNICAL DATA ::
Length 96 cm Height 124 cm
Width 69 cm Weight 35 kg
All Tunturi models and user interfaces meet the requirements of the
EU EMC Directives on electromagnetic compatibility (89/336/EEC)
and electrical equipment designed for use within certain voltage limits
(73/23/EEC). This product therefore carries the CE label.
All Tunturi ergometers meet CEN precision and safety standards (Class
A, EN-957, parts 1 and 5).
TRANSPORT AND STORAGE ::
Follow these instructions when carrying and moving the cycle about,
because lifting it incorrectly may strain your back or risk other accidents:
:: Stand behind the device.
:: Grip the seat with one hand and the handlebar with the other, and
set your foot on the rear support.
:: Tilt the device so that it rests on its transport wheels.
:: Wheel the device to move it on these transport wheels.
:: Lower the device while holding on to the handlebar and remain
behind the device all the time.
If the device is not used for a period of time, the transmission belt may
become temporarily distorted. This can lead to slightly uneven pedalling.
However, after a few minutes of use the effect disappears as the belt
returns to its original form.
To prevent the cycle malfunctioning, store in a dry place with as little
temperature variation as possible and protected from dust.
MAINTENANCE ::
The equipment requires very little maintenance. Check, however, from
time-to-time that all screws and nuts are tight.
:: After exercising, clean the equipment with a soft, absorbent cloth.
Sweat may cause corrosion: we recommend therefore that you
protect all metal surfaces outside the plastic covers with tefl on or
car wax. Do not use solvents. The magnetic brake is based on
magnetic resistance; resistance level is measured electronically and
shown as a watt-reading on the display. Due to the measurement
system, your Tunturi ergometer need not be recalibrated when
assembled, serviced and used according to this owner’s manual.
NOTE! Despite continuous quality control, defects and malfunctions
caused by individual components may occur in the equipment. In most
cases it is unnecessary to take the whole device in for repair, as it is
usually suffi cient to replace the defective part. If the equipment does not
function properly during use, contact your Tunturi dealer immediately.
Always give the model and serial number of your equipment. The
location of the serial number sticker is shown on the inside cover. Please
also state the nature of the problem, conditions of use and purchase date.